Recoil-distance lifetime measurement in 37Cl
نویسندگان
چکیده
2014 Using the recoil-distance technique in the 27Al(12C, 2p)37Cl reaction, mean lives of (19.6 ± 3.0) ps for the 7/2-, 3 103-keV state and (32.8 ± 2.0) ps for the 9/2-, 4 011-keV state in 37Cl have been measured. The strength of the M2 decay from the 3 103 keV level appears to be the strongest among known M2 transitions in 2s-ld nuclei. An upper limit of 0.8 ps for the feeding time in the fusion-evaporation reaction 27Al(12C, pn)37Ar was estimated from an attenuated Dopplershift measurement. LE JOURNAL DE PHYSIQUE TOME 37, JANVIER 1976,
منابع مشابه
Sub-Nanosecond Lifetime Measurement Using the Recoil-Distance Method
The electromagnetic properties of low-lying nuclear states are a sensitive probe of both collective and single-particle degrees of freedom in nuclear structure. The recoil-distance technique provides a very reliable, direct and precise method for measuring lifetimes of nuclear states with lifetimes ranging from less than one to several hundred picoseconds. This method complements the powerful, ...
متن کاملMajor factors affecting the isotopic measurement of chlorine based on the Cs2Cl+ ion by thermal ionization mass spectrometry.
The factors that affect isotopic measurement of chlorine based on Cs2Cl+ ion by thermal ionization mass spectrometry were studied. Graphite is essential for the emission of Cs2Cl+ ion from CsCl. No Cs2Cl+ ions are detected in the absence of graphite on the filament. The emission of Cs2Cl+ ion and the measured 37Cl/35Cl ratio were affected by different varieties of graphite, the pH value of the ...
متن کاملDirect Lifetime Measurements of the Excited States in (72)Ni.
The lifetimes of the first excited 2^{+} and 4^{+} states in ^{72}Ni were measured at the National Superconducting Cyclotron Laboratory with the recoil-distance Doppler-shift method, a model-independent probe to obtain the reduced transition probability. Excited states in ^{72}Ni were populated by the one-proton knockout reaction of an intermediate energy ^{73}Cu beam. γ-ray-recoil coincidences...
متن کاملShape and structure of N=Z 64Ge: electromagnetic transition rates from the application of the recoil distance method to a knockout reaction.
Transition rate measurements are reported for the 2(1)+ and 2(2)+ states in N=Z 64Ge. The experimental results are in excellent agreement with large-scale shell-model calculations applying the recently developed GXPF1A interactions. The measurement was done using the recoil distance method (RDM) and a unique combination of state-of-the-art instruments at the National Superconducting Cyclotron L...
متن کاملPrecision Lifetime Measurements Using the Recoil Distance Method
The recoil distance method (RDM) for the measurements of lifetimes of excited nuclear levels in the range from about 1 ps to 1000 ps is reviewed. The New Yale Plunger Device for RDM experiments is introduced and the Differential Decay Curve Method for their analysis is reviewed. Results from recent RDM experiments on SD bands in the mass-190 region, shears bands in the neutron deficient lead is...
متن کامل