Ion mobility mass spectrometry of peptide, protein, and protein complex ions using a radio-frequency confining drift cell.

نویسندگان

  • Samuel J Allen
  • Kevin Giles
  • Tony Gilbert
  • Matthew F Bush
چکیده

Ion mobility mass spectrometry experiments enable the characterization of mass, assembly, and shape of biological molecules and assemblies. Here, a new radio-frequency confining drift cell is characterized and used to measure the mobilities of peptide, protein, and protein complex ions. The new drift cell replaced the traveling-wave ion mobility cell in a Waters Synapt G2 HDMS. Methods for operating the drift cell and determining collision cross section values using this experimental set up are presented within the context of the original instrument control software. Collision cross sections for 349 cations and anions are reported, 155 of which are for ions that have not been characterized previously using ion mobility. The values for the remaining ions are similar to those determined using a previous radio-frequency confining drift cell and drift tubes without radial confinement. Using this device under 2 Torr of helium gas and an optimized drift voltage, denatured and native-like ions exhibited average apparent resolving powers of 14.2 and 16.5, respectively. For ions with high mobility, which are also low in mass, the apparent resolving power is limited by contributions from ion gating. In contrast, the arrival-time distributions of low-mobility, native-like ions are not well explained using only contributions from ion gating and diffusion. For those species, the widths of arrival-time distributions are most consistent with the presence of multiple structures in the gas phase.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A novel approach to collision-induced dissociation (CID) for ion mobility-mass spectrometry experiments.

Collision induced dissociation (CID) combined with matrix assisted laser desorption ionization-ion mobility-mass spectrometry (MALDI-IM-MS) is described. In this approach, peptide ions are separated on the basis of mobility in a 15 cm drift cell. Following mobility separation, the ions exit the drift cell and enter a 5 cm vacuum interface with a high field region (up to 1000 V/cm) to undergo co...

متن کامل

Shift reagents for multidimensional ion mobility spectrometry-mass spectrometry analysis of complex peptide mixtures: evaluation of 18-crown-6 ether complexes.

18-Crown-6 ether (18C6) is evaluated as a shift reagent for multidimensional ion mobility spectrometry-mass spectrometry (IMS-IMS-MS) analyses of tryptic protein digests. In this approach, 18C6 is spiked into the solution-phase mixture and noncovalent peptide-crown ion complexes are formed by electrospraying the mixture into the gas phase. After an initial mobility separation in the first IMS d...

متن کامل

Overtone mobility spectrometry: part 4. OMS-OMS analyses of complex mixtures.

A new, two-dimensional overtone mobility spectrometry (OMS-OMS) instrument is described for the analysis of complex peptide mixtures. OMS separations are based on the differences in mobilities of ions in the gas phase. The method utilizes multiple drift regions with modulated drift fields such that only ions with appropriate mobilities are transmitted to the detector. Here we describe a hybrid ...

متن کامل

Coupling high-pressure MALDI with ion mobility/orthogonal time-of-flight mass spectrometry.

A new ion mobility/time-of-flight mass spectrometer employing a high-pressure MALDI source has been designed and tested. The prototype instrument operates at a source/drift cell pressure of 1-10 Torr helium, resulting in a mobility resolution of approximately 25. A small time-of-flight mass spectrometer (20 cm) with a mass resolution of up to 200 has been attached to the drift cell to identify ...

متن کامل

Extracted Fragment Ion Mobility Distributions: A New Method for Complex Mixture Analysis.

A new method is presented for constructing ion mobility distributions of precursor ions based upon the extraction of drift time distributions that are monitored for selected fragment ions. The approach is demonstrated with a recently designed instrument that combines ion mobility spectrometry (IMS) with ion trap mass spectrometry (MS) and ion fragmentation, as shown in a recent publication [J. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Analyst

دوره 141 3  شماره 

صفحات  -

تاریخ انتشار 2016