Application of Circumferential Compression Device (Binder) in Pelvic Injuries: Room for Improvement
نویسندگان
چکیده
INTRODUCTION The use of a noninvasive pelvic circumferential compression device (PCCD) to achieve pelvic stabilization by both decreasing pelvic volume and limiting inter-fragmentary motion has become commonplace, and is a well-established component of Advanced Trauma Life Support (ATLS) protocol in the treatment of pelvic ring injuries. The purpose of this study was to evaluate the following: 1) how consistently a PCCD was placed on patients who arrived at our hospital with unstable pelvic ring injuries; 2) if they were placed in a timely manner; and 3) if hemodynamic instability influenced their use. METHODS We performed an institutional review board-approved retrospective study on 112 consecutive unstable pelvic ring injuries, managed over a two-year period at our Level I trauma center. Our hospital electronic medical records were used to review EMT, physician, nurses', operative notes and radiographic images, to obtain information on the injury and PCCD application. The injuries were classified by an orthopaedic trauma surgeon and a senior orthopaedic resident. Proper application of a pelvic binder using a sheet is demonstrated. RESULTS Only 47% of unstable pelvic fractures received PCCD placement, despite being the standard of care according to ATLS. Lateral compression mechanism pelvic injuries received PCCDs in 33% of cases, while anterior posterior compression (APC) and vertical shear (VS) injuries had applications in 63% of cases. Most of these PCCD devices were applied after imaging (72%). Hemodynamic instability did not influence PCCD application. CONCLUSION PCCD placement was missed in many (37%) of APC and VS mechanism injuries, where their application could have been critical to providing stability. Furthermore, to provide rapid stability, pelvic circumferential compression devices should be applied after secondary examination, rather than after receiving imaging results. Better education on timing and technique of PCCD placement at our institution is required to improve treatment of pelvic ring injuries.
منابع مشابه
Use of the trauma pelvic orthotic device (T-POD) for provisional stabilisation of anterior-posterior compression type pelvic fractures: a cadaveric study.
OBJECTIVE To demonstrate that a commercially available pelvic binder the trauma pelvic orthotic device (T-POD) is an effective way to provisionally stabilise anterior-posterior compression type pelvic injuries. METHODS Rotationally unstable pelvic injuries were created in 12 non-embalmed human cadaveric specimens. Each pelvis was then stabilised first with a standard bed sheet wrapped circumf...
متن کاملEmergent stabilization of pelvic ring injuries by controlled circumferential compression: a clinical trial.
BACKGROUND Pelvic ring injuries are associated with a high incidence of mortality mainly due to retroperitoneal hemorrhage. Early stabilization is an integral part of hemorrhage control. Temporary stabilization can be provided by a pelvic sheet, sling, or an inflatable garment. However, these devices lack control of the applied circumferential compression. We evaluated a pelvic circumferential ...
متن کاملNoninvasive reduction of open-book pelvic fractures by circumferential compression.
OBJECTIVES To determine the efficacy and optimal application parameters of circumferential compression to reduce external rotation-type pelvic fractures. DESIGN Biomechanical investigation on human cadaveric specimens. SETTING Biomechanics laboratory. INTERVENTION Partially stable and unstable external rotation injuries of the pelvic ring (OTA classification 61-B1 and 61-C1) were created ...
متن کاملComparison of three different pelvic circumferential compression devices: a biomechanical cadaver study.
BACKGROUND Pelvic circumferential compression devices are designed to stabilize the pelvic ring and reduce the volume of the pelvis following trauma. It is uncertain whether pelvic circumferential compression devices can be safely applied for all types of pelvic fractures because the effects of the devices on the reduction of fracture fragments are unknown. The aim of this study was to compare ...
متن کاملAccurate placement of a pelvic binder improves reduction of unstable fractures of the pelvic ring.
The aim of this study was to assess the accuracy of placement of pelvic binders and to determine whether circumferential compression at the level of the greater trochanters is the best method of reducing a symphyseal diastasis. Patients were identified by a retrospective review of all pelvic radiographs performed at a military hospital over a period of 30 months. We analysed any pelvic radiogra...
متن کامل