Evaluation of the PG-Numeric assay for semi-automated analysis for phosphatidylglycerol in amniotic fluid.

نویسندگان

  • J F Chapman
  • J C Phillips
  • M A Rosenthal
  • W N Herbert
چکیده

We evaluated the performance of the PG-Numeric (PGN; Isolab, Inc.) enzymatic assay for phosphatidylglycerol (PG) adapted for semi-automated analysis on the Cobas-Bio (Roche) centrifugal analyzer. We evaluated precision, linearity, and potential interference from endogenous glycerol. In addition, we compared the results of the PGN assay with those for two other PG assays. Amniostat-FLM (AFLM; Hana Biologics) and phosphatidylglycerol/sphingomyelin ratio (PG/S), on amniotic fluid samples from 51 patients. Within-run and total CVs for the PGN test (n = 80) were respectively 8.6% and 11.4% for PG at 2.6 mumol/L, and 4.5% and 6.2% at 7.3 mumol/L. The PGN test exhibited no significant deviation from linearity between PG concentrations of 0.4 and 15 mumol/L. Endogenous glycerol up to 500 mumol/L did not affect PGN results significantly. Results of the PGN assay compared favorably with those of the other PG assays for tests of fetal lung maturation. The Cobas-Bio adaptation of the PGN test performed well analytically and clinically, and allowed the determination of PG in less than 1 h.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Interference by endogenous glycerol in an enzymatic assay of phosphatidylglycerol in amniotic fluid.

We investigated the possibility of interference by endogenous glycerol with the enzymatic measurement of phosphatidylglycerol in amniotic fluid. Phosphatidylglycerol is an important indicator of fetal lung maturity. The concentrations of glycerol and phosphatidylglycerol in amniotic fluid were measured by using a coupled enzymatic assay with and without phospholipase D (EC 3.1.4.4). The precisi...

متن کامل

Enzymatic measurement of phosphatidylglycerol in amniotic fluid.

We describe an enzymatic method for measuring phosphatidylglycerol (PG) at concentrations as low as 0.2 mumol/L in amniotic fluid. Amniotic fluid (1.5 mL) is centrifuged at 10,000g for 20 min to obtain a lamellar body pellet, which is reconstituted with 0.5 mL of buffer. The PG is measured by a two-step enzymatic scheme. Recovery studies demonstrated that the pellet contains > 97% of the PG pre...

متن کامل

Cost Function Modelling for Semi-automated SC, RTG and Automated and Semi-automated RMG Container Yard Operating Systems

This study analyses the concept of cost functions for semi-automated Straddle Carrier (SC), Rubber Tyred Gantry (RTG) and automated Rail Mounted Gantry (RMG) container yard operating cranes. It develops a generic cost based model for a pair-wise comparison, analysis and evaluation of economic efficiency and effectiveness of container yard equipment to be used for decision-making by terminal pla...

متن کامل

Evaluation of the Amniostat-FLM assay for assessment of fetal lung maturity.

Results of the "Amniostat-FLM" assay, a rapid semiquantitative test for phosphatidylglycerol, were compared with determinations of the lecithin/sphingomyelin (L/S) ratio, with phosphatidylglycerol measured by two-dimensional thin-layer chromatography, and with results of the "shake test" for 94 specimens of amniotic fluid. Correlation between results with the Amniostat and the other tests was e...

متن کامل

Biochemical evaluation of amniotic fluid during different stages of gestation in the goat

To study changes in concentrations of some biochemical factors of amniotic fluid, 115 normal goat uteri at different stages of pregnancy were collected from slaughterhouse. After expelling of each fetus accompanied by fetal membranes, 10 ml amniotic fluid was taken from amniotic sac for biochemical analysis. Then approximate ages of fetuses were calculated by using age estimation formula. At fi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 36 11  شماره 

صفحات  -

تاریخ انتشار 1990