Validation of thoracic impedance cardiography by echocardiography in healthy late pregnancy
نویسندگان
چکیده
BACKGROUND Assessment of stroke volume (SV) is often necessary in clinical and research settings. The clinically established method for SV assessment in pregnancy is echocardiography, but given its limitations, it is not always an appropriate measurement tool. Thoracic impedance cardiography (ICG) allows continuous, non-invasive SV assessment. However, SV determination relies on assumptions regarding the thoracic shape that may mean the algorithm is not valid in pregnancy. The available data regarding the validity of ICG against an established reference standard using modern SV algorithms are both limited and conflicting. We aimed to test the validity of ICG in a clinically realistic setting in late pregnancy using echocardiography. METHODS Twenty-nine women in late pregnancy underwent standard echocardiography assessments with simultaneous ICG measurement. Agreement between devices was tested using Bland-Altman analysis. RESULTS Bland-Altman analysis of the relationship between ICG and echocardiography demonstrated that the 95% limits of agreement exceeded acceptable or expected ranges. Measures of maternal and fetal anthropometry do not account for the lack of agreement. CONCLUSIONS Absolute values of SV as determined by ICG are not valid in pregnancy. Further work is required to examine the ability of ICG to assess relative changes in maternal haemodynamics in late pregnancy.
منابع مشابه
Impedance pneumography: noise as signal in impedance cardiography.
Thoracic impedance is modulated by events within the respiratory cycle, which represents a source of "noise" in impedance cardiography. Respiration itself, however, is a physiological rhythm of interest to psychophysiologists. We report here methods and validation for deriving impedance pneumographic measures of respiration from impedance cardiography signals, based on standard tetrapolar band ...
متن کاملComparison of electrical velocimetry and transoesophageal Doppler echocardiography for measuring stroke volume and cardiac outputy
Background. Impedance cardiography (ICG) has been used extensively to estimate stroke volume (SV) and cardiac output (CO) from changes of thoracic electrical bioimpedance (TEB). However, studies comparing ICG with reference methods have questioned the reliability of this approach. Electrical velocimetry (EV) provides a new algorithm to calculate CO from variations in TEB. As the transoesophagea...
متن کاملImpedance cardiography - Old method, new opportunities. Part I. Clinical applications.
Monitoring of cardiovascular hemodynamic changes requires a very expensive and highly specialized equipment and skilled medical personnel. Up to the present time, an inexpensive, non-invasive and easy-to-use method which, like Doppler echocardiography, magnetic resonance angiography or radionuclide imaging, would assess hemodynamics of the cardiovascular system was not available. A method known...
متن کاملVenous pulse transit time in normal pregnancy and preeclampsia.
Uncomplicated pregnancies (n = 16) were evaluated longitudinally and compared to early- (n = 12) and late-onset (n = 14) preeclampsia patients, assessed once at diagnosis. Pulse transit time (PTT), equivalent to pulse wave velocity, was measured as the time interval between corresponding characteristics of electrocardiography and Doppler waves, corrected for heart rate, at the level of renal in...
متن کاملقلب نگاری امپدانسی روشی برای پایش غیرتهاجمی حجم ضربه ای: یک مطالعه ی مقدماتی
Abstract Background: Impedance cardiography (ICG) is a simple and inexpensive technique for non-invasive and continues measurement of stroke volume. Due to non-invasive nature, ICG is becoming increasingly used in research and clinical applications. With regard to lack of domestic impedance cardiograph and limited similar imported products in the country, an inexpensive and portable protot...
متن کامل