HOM LOSSES AT THE INTERACTION REGION rc OF THE B FACTORY
نویسنده
چکیده
Masking at the Interaction Region (IR) will presumably reduce the synchrotron radiation background in the detector. One possible layout of the IR for the B factory, depicted in Fig. 1, shows a rather complicated system of masks. A bunch passing each mask will generate RF waves. These waves (usually called higher order modes, HOMs) will be absorbed in the beam pipe wall producing additional heating and, interacting with the beam, kicking particles in the radial and azimuthal directions. This may change the bunch motion and its emittance. These effects are estimated in the present note.
منابع مشابه
Impedance Budget for the Kek B-factory
In this paper, we deal with impedances of various beamline elements in the KEK B-Factory. We will also discuss the power deposition generated by a beam in the form of the higher-ordermode (HOM) losses by interacting with its surroundings.
متن کاملHOM Heating at the PEP-II B-Factory IR Beryllium Vacuum Pipe
The higher-order-mode (HOM) heating of the central beryllium beam pipe in the PEP-II B-Factory interaction region is evaluated. Both single and multi-bunch effects are considered. While single-bunch heating is not an issue, resonant heating due to multiple bunch passages is found to be unacceptable. Modifying the IR configuration around the central pipe has been shown to alleviate this problem....
متن کاملDesign of Hom Power Absorbers for the Kek B-factory
The Higher-Order-Mode (HOM) power deposition is one of most crucial problems in the KEK B-factory to achieve a total beam current of 2.6A at the Low Energy Ring (LER). The estimate shows that the HOM power of about 20 kW can pass at any point in the arc of the ring. A particular worry is the Interaction Point (IP) where the maximum tolerable heat deposition of the IP chamber is only 200 W. Two ...
متن کاملSeismic Damage Assessment of RC Buildings Subjected to the Rotational Ground Motion Records Considering Soil-Structure Interaction
The significance of the seismic rotational components have been overlooked in the seismic evaluation of structural behavior. As researchers have measured seismic components more accurately using sensitive rotational velocity sensor, it was observed that the magnitude of rotational components is considerable and could not be neglected. Hence, some parts of seismic damage or failure of structures...
متن کاملA New Approach for Numerical Analysis of the RC Shear Walls Based on Timoshenko Beam Theory Combined with Bar-Concrete Interaction
In this paper, a new approach for nonlinear numerical modelling of the reinforced concrete shear walls with consideration of bar-concrete interaction and shear deformation is proposed. Bar and concrete stress-strain relations, the bar-concrete interaction, the shear stress-strain relation and, also, their cyclic behavior including the strength degradation and stiffness degradation are adopted a...
متن کامل