Changes in the rapidly extracted auditory evoked potentials index and the bispectral index during sedation induced by propofol or midazolam under epidural block.

نویسندگان

  • S J Ge
  • X L Zhuang
  • Y T Wang
  • Z D Wang
  • H T Li
چکیده

BACKGROUND The bispectral index (BIS) and the rapidly extracted auditory evoked potentials index (A-line ARX Index or AAI) have been proposed as methods to measure the depth of sedation. A prospective study was designed to assess the performance of both these methods for measuring the depth of sedation induced by propofol or midazolam under epidural block. METHODS Thirty-two ASA I and II adult patients undergoing elective gynaecological surgery under low-thoracolumbar epidural block were studied. Eighteen patients received propofol (Group P: 20 mg bolus every 3 min) and 14 received midazolam (Group M: 0.5 mg bolus every 5 min) until an observer's assessment of alertness/sedation (OAA/S) scale score of 1 was achieved. AAI and BIS were monitored for different OAA/S scores. RESULTS AAI and BIS decreased and increased following the changes on the patients' OAA/S scores and correlated with sedation significantly. During the onset phase, the coefficients of Spearman's rank correlation for AAI and BIS were respectively 0.958 and 0.898 (P < 0.001) for Group P, and 0.973 and 0.945 (P < 0.001) for Group M. During the recovery phase in Group P, the coefficients were respectively 0.946 and 0.702 (P < 0.001). Linear regression analysis showed that both AAI and BIS were linearly related to the OAA/S scores. The coefficients of Spearman's rank correlation and linear regression for AAI were all greater than those for BIS (P < 0.05). CONCLUSIONS Both AAI and BIS correlated well with the depth of sedation induced by propofol or midazolam under epidural block. AAI may be more valuable when monitoring depth of sedation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Coadministration of propofol and midazolam decreases bispectral index value as a result of synergic muscle relaxant action on the motor system.

To the Editor:—We read with great scientific interest the study of Vuyk et al. reporting three cases in which volunteers receiving combinations of propofol and midazolam remained responsive to verbal command although the Bispectral Index (BIS) values were at, or just above, 40, the area considered to be associated with adequate hypnosis for surgery (BIS, 40–60). Vuyk et al. note that the electr...

متن کامل

Normal bispectral index values in healthy volunteers.

To the Editor:—We read with great scientific interest the study of Vuyk et al. reporting three cases in which volunteers receiving combinations of propofol and midazolam remained responsive to verbal command although the Bispectral Index (BIS) values were at, or just above, 40, the area considered to be associated with adequate hypnosis for surgery (BIS, 40–60). Vuyk et al. note that the electr...

متن کامل

Block-dependent sedation during epidural anaesthesia is associated with delayed brainstem conduction.

BACKGROUND Neuraxial anaesthesia produces a sedative and anaesthetic-sparing effect. Recent evidence suggests that spinal cord anaesthesia modifies reticulo-thalamo-cortical arousal by decreasing afferent sensory transmission. We hypothesized that epidural anaesthesia produces sensory deafferentation-dependent sedation that is associated with impairment of brainstem transmission. We used brains...

متن کامل

Auditory processing during deep propofol sedation and recovery from unconsciousness.

OBJECTIVE Using evoked potentials, this study investigated effects of deep propofol sedation, and effects of recovery from unconsciousness, on the processing of auditory information with stimuli suited to elicit a physical MMN, and a (music-syntactic) ERAN. METHODS Levels of sedation were assessed using the Bispectral Index (BIS) and the Modified Observer's Assessment of Alertness and Sedatio...

متن کامل

Bispectral index monitoring during sedation with sevoflurane, midazolam, and propofol.

BACKGROUND Bispectral Index (BIS) has been used to measure sedation depth. Ideally, to guide anesthetic management, range of BIS scores at different sedation levels should not overlap, and BIS should be independent of drug used. This study assessed ability of BIS to predict sedation depth between sevoflurane, propofol, and midazolam. Quality of recovery was also compared. METHODS Patients und...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British journal of anaesthesia

دوره 89 2  شماره 

صفحات  -

تاریخ انتشار 2002