Simulation of the Beating Heart Based on Physically Modeling a Deformable Balloon
نویسندگان
چکیده
The motion of the beating heart is complex and creates artifacts in SPECT and x-ray CT images. Phantoms such as the Jaszczak Dynamic Cardiac Phantom are used to simulate cardiac motion for evaluation of acquisition and data processing protocols used for cardiac imaging. Two concentric elastic membranes filled with water are connected to tubing and pump apparatus for creating fluid flow in and out of the inner volume to simulate motion of the heart. In the present report, the movement of two concentric balloons is solved numerically in order to create a computer simulation of the motion of the moving membranes in the Jaszczak Dynamic Cardiac Phantom. A system of differential equations, based on the physical properties, determine the motion. Two methods are tested for solving the system of differential equations. The results of both methods are similar providing a final shape that does not converge to a trivial circular profile. Finally, a tomographic imaging simulation is performed by acquiring static projections of the moving shape and reconstructing the result to observe motion artifacts. Two cases are taken into account: in one case each projection angle is sampled for a short time interval and the other case is sampled for a longer time interval. The longer sampling acquisition shows a clear improvement in decreasing the tomographic streaking artifacts. keywords: Differential Equation, Numerical Method, Physically Based Modeling, Tomography Artifacts
منابع مشابه
Use of Carbon dioxide versus air blower in on-pump beating-heart coronary artery bypass surgery
Introduction: The use of carbon dioxide blower has been recognized as the standard of care in patients undergoing beating coronary artery bypass grafting (CABG) due to higher solubility and lower risk of embolization. On the other hand, the compressed air blower has gone out of use since air can be easily trapped and is less soluble which can cause coronary embolism. The prese...
متن کاملOn-Pump Beating Coronary Artery Bypass in High Risk Coronary Patients
Background: There are some conflicting results with Conventional Coronary Artery Bypass Grafts (CCABG) with arrested heart in coronary high-risk patients. Moreover, performing off-pump CABG in these cases may be associated with serious complications. The objective of this study is to evaluate the efficacy of the on-pump beating CABG (OPBCABG) in coronary high-risk patients in comparison with th...
متن کاملControllable Simulation of Deformable Objects Using the Heuristic Optimal Control Method
Physically-based simulation techniques have been widely used in computer graphics because it creates highly realistic animation. However, due to the limitation of passive simulation and simplified modeling methods, it is very difficult to control the behavior of deformable objects directly. Ability to control the behavior of deformable objects is a very important feature for an effective simula...
متن کاملMeasurement-Based Modeling and Fabrication of Deformable Materials for Human Faces
This thesis investigates the combination of data-driven and physically based techniques for acquiring, modeling, and animating deformable materials, with a special focus on human faces. Furthermore, based on these techniques, we introduce a data-driven process for designing and fabricating materials with desired deformation behavior. Realistic simulation behavior, surface details, and appearanc...
متن کاملReal-time control of physically based simulations using gentle forces Citation
Recent advances have brought real-time physically based simulation within reach, but simulations are still difficult to control in real time. We present interactive simulations of passive systems such as deformable solids or fluids that are not only fast, but also directable: they follow given input trajectories while simultaneously reacting to user input and other unexpected disturbances. We a...
متن کامل