Evaluation of automated statistical shape model based knee kinematics from biplane fluoroscopy.

نویسندگان

  • Nora Baka
  • Bart L Kaptein
  • J Erik Giphart
  • Marius Staring
  • Marleen de Bruijne
  • Boudewijn P F Lelieveldt
  • Edward Valstar
چکیده

State-of-the-art fluoroscopic knee kinematic analysis methods require the patient-specific bone shapes segmented from CT or MRI. Substituting the patient-specific bone shapes with personalizable models, such as statistical shape models (SSM), could eliminate the CT/MRI acquisitions, and thereby decrease costs and radiation dose (when eliminating CT). SSM based kinematics, however, have not yet been evaluated on clinically relevant joint motion parameters. Therefore, in this work the applicability of SSMs for computing knee kinematics from biplane fluoroscopic sequences was explored. Kinematic precision with an edge based automated bone tracking method using SSMs was evaluated on 6 cadaveric and 10 in-vivo fluoroscopic sequences. The SSMs of the femur and the tibia-fibula were created using 61 training datasets. Kinematic precision was determined for medial-lateral tibial shift, anterior-posterior tibial drawer, joint distraction-contraction, flexion, tibial rotation and adduction. The relationship between kinematic precision and bone shape accuracy was also investigated. The SSM based kinematics resulted in sub-millimeter (0.48-0.81mm) and approximately 1° (0.69-0.99°) median precision on the cadaveric knees compared to bone-marker-based kinematics. The precision on the in-vivo datasets was comparable to that of the cadaveric sequences when evaluated with a semi-automatic reference method. These results are promising, though further work is necessary to reach the accuracy of CT-based kinematics. We also demonstrated that a better shape reconstruction accuracy does not automatically imply a better kinematic precision. This result suggests that the ability of accurately fitting the edges in the fluoroscopic sequences has a larger role in determining the kinematic precision than that of the overall 3D shape accuracy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accuracy of a contour-based biplane fluoroscopy technique for tracking knee joint kinematics of different speeds.

While measuring knee motion in all six degrees of freedom is important for understanding and treating orthopaedic knee pathologies, traditional motion capture techniques lack the required accuracy. A variety of model-based biplane fluoroscopy techniques have been developed with sub-millimeter accuracy. However, no studies have statistically evaluated the consistency of the accuracy across motio...

متن کامل

Preliminary model-based validation of a biplane fluoroscopy system

Background Biplane fluoroscopy can directly track the motion of bones and therefore measure joint kinematics. Our prior markerbased work has demonstrated the ability of our system to accurately and precisely track the motion of known objects (i.e., tantalum beads) [1]. In this study, we present the preliminary bone-based validation of our system by tracking the bones of the foot from cadaveric ...

متن کامل

Tibio-femoral Kinematics of Soft and Stiff Landings: A Biplane Fluoroscopy Study

INTRODUCTION: Though the exact mechanism of non contact anterior cruciate ligament (ACL) has not been fully clarified, several recent studies have suggested individuals who land with a stiff landing profile, defined as reduced knee flexion angles, may be at higher risk of ACL injury than individuals who land more soft [1,2]. The concepts and theories developed from these and other non-contact A...

متن کامل

Theoretical accuracy of model-based shape matching for measuring natural knee kinematics with single-plane fluoroscopy.

Quantification of knee motion under dynamic, in vivo loaded conditions is necessary to understand how knee kinematics influence joint injury, disease, and rehabilitation. Though recent studies have measured three-dimensional knee kinematics by matching geometric bone models to single-plane fluoroscopic images, factors limiting the accuracy of this approach have not been thoroughly investigated....

متن کامل

Comparison of the effects of external instruction exercises in combination with hip-knee strengthening on gait kinematics in patients with patellofemoral pain syndrome: a randomized clinical trial.

Aims and Background: Patellofemoral pain syndrome is one of the most common musculoskeletal disorders, and is related to biomechanical factors of the lower extremities. The purpose of this study was to compare the effect of hip and knee strengthening with internal instruction exercises on pain and dynamic knee valgus in patients with Patellofemoral pain syndrom. Materials and Methods: 50 men a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of biomechanics

دوره 47 1  شماره 

صفحات  -

تاریخ انتشار 2014