A dedicated high-resolution PET imager for plant sciences.
نویسندگان
چکیده
PET provides an in vivo molecular and functional imaging capability that could be valuable for studying the interaction of plants in changing environments at the whole-plant level. We have developed a dedicated plant PET imager housed in a plant growth chamber (PGC), which provides a fully controlled environment. The system currently contains two types of scintillation detector modules from commercial small animal PET scanners: 84 microPET® detectors, which are made with scintillation crystal arrays of 2.2 mm(3) × 2.2 mm(3) × 10 mm(3) crystals to provide a large detection area; and 32 Inveon™ detectors, which are made with scintillation crystal arrays of 1.5 mm(3) × 1.5 mm(3) × 10 mm(3) crystals to provide higher spatial resolution. The detector modules are configured to form two half-rings, which provide a 15 cm-diameter trans-axial field of view (FOV) for dynamic tomographic imaging of small plants. Alternatively, the Inveon detectors can be reconfigured to form quarter-rings, which provide a 25 cm FOV using step-and-shoot motion. The imager contains two linear stages that move detectors vertically at different heights for multisection scanning, and two rotation stages to collect coincidence events from all angles when using the step-and-shoot acquisition. The detector modules and mechanical components of the imager are housed inside a PGC that regulates the environmental parameters. The system has a typical energy resolution of 15% for the Inveon detectors and 24% for the microPET detectors, timing resolution of 1.8 ns, and sensitivity of 1.3%, 1.4% and 3.0% measured at the center of the FOV, 5 cm off to the larger half-ring and 5 cm off to the smaller half-ring, respectively (with a 350-650 keV energy window and 3.1 ns timing window). The system's spatial resolution is capable of resolving rod sources of 1.25 mm diameter spaced 2.5 mm apart (center to center) using the ML-EM reconstruction algorithm. Preliminary imaging experiments using soybean and wild type and mutant maize labeled with (11)CO2 produced high-quality dynamic PET images that reveal the translocation and distribution patterns of photoassimilates. This system can be used to provide an in vivo molecular and functional imaging capability for plant research.
منابع مشابه
Combined 3D PET and Optical Projection Tomography Techniques for Plant Root Phenotyping
New imaging techniques are in great demand for investigating underground plant roots systems which play an important role in crop production. Compared with other nondestructive imaging modalities, PET can image plant roots in natural soil and produce dynamic 3D functional images which reveal the temporal dynamics of plant-environment interactions. In this study, we combined PET with optical pro...
متن کاملValidation and evaluation of a GATE model for MAMMI PET scanner
Introduction:MAMMI is a dedicated PET based on high resolution detectors placed close to the breast. In this study, we presented a GATE model for the simulation of MAMMI scanner and model its performance of the MAMMI based on an adaptation of the NU 4-2008 NEMA standard. Methods:A detailed of geometry MAMMI system that uses scintillation crystals coupled...
متن کاملDedicated brain PET system of PET/MR for brain research.
Institute of Medical Physics, Department of Engineering Physics, Tsinghua University, Beijing, China This work is to replace PET ring in human brain PET/MR system with a dedicated wearable PET insert, aimed at improving both patient feasibility and system performance for brain imaging. The designed PET/MR system includes two parts: the inside parts, including a radio frequency (RF) coil and PET...
متن کاملRecent Advances in PET-MR Hybrid contrast agent
Introduction: All of the Imaging modalities have advantages and disadvantages alone. So if we want to have the best and perfect image, combining these modalities produces something we desired. PET-MR images consist of morphologic and metabolic data. MRI and PET provide high spatial and contrast resolution and high sensitivity and molecular information respectively. Hybrid PET-...
متن کاملValue of Dedicated Head and Neck 18F-FDG PET/CT Protocol in Detecting Recurrent and Metastatic Lesions in Post-surgical Differentiated Thyroid Carcinoma Patients with High Serum Thyroglobulin Level and Negative 131I Whole-body Scan
Objective(s): In clinical practice, approximately 10-25% of post-surgical differentiated thyroid carcinoma (DTC) patients with high serum thyroglobulin (Tg) and negative 131I whole-body scan (WBS) have poor prognosis due to recurrent or metastatic lesions after radioactive iodine treatment. The purpose of this study was to evaluate the value of 18F-FDG PET/CT scan in DTC patients with high seru...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Physics in medicine and biology
دوره 59 19 شماره
صفحات -
تاریخ انتشار 2014