Accuracy of temporal artery thermometry in neonatal intensive care infants.

نویسندگان

  • Gail Lee
  • Diane Flannery-Bergey
  • Kris Randall-Rollins
  • Diane Curry
  • Sandra Rowe
  • Megan Teague
  • Cynthia Tuininga
  • Sharon Schroeder
چکیده

PURPOSE To determine the accuracy of temporal artery and axillary temperatures and the discomfort level of stable neonates during temperature measurement. SUBJECTS Convenience sample of neonates between the ages of 32 and 40 weeks' gestation cared for in an isolette or crib. DESIGN A method-comparison design was used to compare different methods for noninvasive temperature monitoring (infra-red temporal artery; axillary electronic) to core body temperatures (indwelling rectal probe). MAIN OUTCOME MEASURE Bias and precision of test temperature devices (temporal artery; axillary). RESULTS Bias and precision for the temporal artery and axillary devices were 0.30 ± 0.44 and 0.28 ± 0.33, respectively. Analysis of variance found significant differences between both temporal and axillary temperatures compared to rectal temperatures (P < .01). Statistical differences were small and did not represent a clinically important difference. No statistical difference was found between temporal artery and axillary temperatures (P = .81). Increases in neonate discomfort after temperature measurement were significantly greater with axillary than increases after temporal artery temperature measurement (P = .03). CONCLUSIONS This study found that body temperature measured with the temporal artery thermometer was similar to temperatures obtained with an axillary thermometer in stable, afebrile neonates. The use of temporal artery thermometry appears to be an acceptable approach for noninvasive temperature measurement in neonates, which causes less discomfort in neonates.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accuracy of a noninvasive temporal artery thermometer for use in infants.

OBJECTIVES To assess the accuracy of a new noninvasive temporal artery (TA) thermometer in infants; to compare the accuracy of the TA thermometer with that of a tympanic thermometer, using rectal thermometry as the criterion standard; and to compare the tolerability of the TA thermometer with that of the tympanic and rectal thermometers. DESIGN Prospective evaluation of the accuracy of TA and...

متن کامل

Correlations of Handling Procedures and Sleep Patterns of the Infants Admitted to the Neonatal Intensive Care Unit

Background: The present study aimed to assess handling procedures and their effects on the sleep-wake time in the preterm infants admitted to the neonatal intensive care unit (NICU). Methods: This observationalcross-sectional study was conducted in the NICU ofVali-e-Asr Teaching Hospital affiliated to Tehran University of Medical Sciences (TUMS), Iran in 2016. Sample population consisted of 15...

متن کامل

The effect of Yakson touch on neonatal weight of premature infants admitted to the intensive care unit of Taleghani Hospital in Gonbad Kavous 2020

.1 Semnani N, Hojjati H, Akhoundzadeh G. The Effect of Yakson Touch on Pain Control Due to Nasogastric Intubation in Premature Infants Admitted to the Neonatal Intensive Care Unit of Taleghani Gonbad Hospital in 2019. arumshcj. 2020;22(2):93-101. .2 Hanieh Sajadi GAHH. The Effect of Empowerment Program on Participation of Mothers with Premature Infants Hospitalized in Neonatal Intensive Care U...

متن کامل

Nurses' Experiences of Palliative Care in the Neonatal Intensive Care Unit

Background & purpose: Despite recent advances in infant care technology, a number of infants are at risk in infancy period and need to palliative care. Nurses are responsible for the palliative care of the infants and the families. Therefore, the present study was conducted to explain the Nurses' Experiences of Palliative Care in the Neonatal Intensive Care Unit. Materials and Methods: This st...

متن کامل

Evaluation of Suitable Connection Point of Skin Probe for Temperature Control in Premature Infants under Radiant Heating Admitted to Neonatal Intensive Care Unit

Background and Objectives: Placement of skin heat probe for continuous monitoring of infant body temperature is one of the main components of neonatal care. Therefore, managing the body temperature of newborns under radiation warmers requires a lot of attention from nurses to prevent unwanted complications. The aim of this study was to determine the appropriate connection point of skin probe fo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Advances in neonatal care : official journal of the National Association of Neonatal Nurses

دوره 11 1  شماره 

صفحات  -

تاریخ انتشار 2011