Portable software tools for 3D radiation therapy planning.

نویسندگان

  • J Jacky
  • I Kalet
  • J Chen
  • J Coggins
  • S Cousins
  • R Drzymala
  • W Harms
  • M Kahn
  • S Kromhout-Schiro
  • G Sherouse
چکیده

PURPOSE Produce a collection of software tools (computer programs) that support three-dimensional (3D) radiation therapy planning. The tools are not a complete 3D planning system. Instead, they work with any 3D planning system that meets certain minimal specifications. The tools assist in deriving anatomic data from images, generating target volume contours, evaluating treatment plans, and verifying accurate treatment delivery. The tools are portable: they can run without source code changes in any computing environment that provides a library of functions and data definitions called the Foundation. The Foundation couples the portable tools to the (usually nonportable) file system and dose calculation associated with a particular 3D planning system. METHODS AND MATERIALS Tools were written at three different (geographically separated) institutions. Software developers from all three sites specified the Foundation. The programmers' interface to the Foundation is portable, but a Foundation implementation need not be portable. Each group implemented a Foundation adapted to the (different) 3D planning system used at their site. RESULTS All tools run at all three sites without source code changes. Each Foundation was implemented in a few person-months of programming effort. The program text and documentation for the tools have been placed in the public domain. CONCLUSIONS It is practical and economical to produce portable radiotherapy treatment planning tools. Providers of 3D planning programs should offer Foundations for their systems, so they can be used with tools. Researchers considering new computer programs should write them as tools, so they can work with any 3D planning system.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Radiobiological Models for Radiation Therapy Plans of Prostate Cancer: Three-dimensional Conformal versus Intensity Modulated Radiation Therapy

Purpose: In the current study, using different radiobiological models, tumor control probability (TCP) and normal tissue complication probability (NTCP) of radiotherapy plans were calculated for three-dimensional conformal radiation therapy (3D-CRT) and intensity modulated radiation therapy (IMRT) of prostate cancer.Methods and Materials: 10 prostate plans were randomly selected among patients ...

متن کامل

Assessment and Comparison of Homogeneity and Conformity Indexes in Step-and-Shoot, Compensator-Based Intensity Modulated Radiation Therapy (IMRT) and Three-Dimensional Conformal Radiation Therapy (3D CRT) in Prostate Cancer

Introduction: Intensity modulated radiation therapy (IMRT) and three-dimensional conformal radiation therapy (3D CRT) are two treatment modalities in prostate cancer, which provide acceptable dose distribution in tumor region with sparing the surrounding normal tissues. IMRT is based on inverse planning optimization; in which, intensity of beams is modified by using multileaf c...

متن کامل

3D-Conformal Radiation Therapy and Intensity-Modulated Radiation Therapy Techniques for Laryngeal Cancer Taking Parotid Glands as Organ at Risk

Background: Three-dimensional conformal radiotherapy (3D-CRT) and intensity-modulated radiotherapy (IMRT) techniques are used for the treatment of patients with laryngeal cancer. Objective: This study aimed to investigate the effects of these 2 treatment techniques on the planning target volume (PTV) (laryngeal cancer), dose homogeneity, dose of organs at...

متن کامل

Comparison of Volumetric Modulated Arc Therapy and Three-Dimensional Conformal Radiotherapy in Postoperative High-Grade Glioma: A Dosimetric Comparison

Introduction: We aimed to dosimetrically compare three-dimensional conformal radiotherapy (3D-CRT) and volumetric modulated arc therapy (VMAT) in terms of planning target volume (PTV) coverage, organ at risk (OAR) sparing, and conformity index (CI). Material and Methods: Planning data of 26 high grade glioma (HGG) patients were used. Prescrib...

متن کامل

Dosimetric Comparison of 3D Tangential Radiotherapy of Post-Lumpectomy Breast at Two Different Energies

Introduction: Radiation therapy following breast conserving surgery is one of the most common procedures performed in any radiation oncology department. A tangential parallel-opposed pair is almost always the technique of choice for this purpose. This technique is often performed based on 3D treatment planning. The aim of this study was to compare 3D treatment planning for two different energie...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • International journal of radiation oncology, biology, physics

دوره 30 4  شماره 

صفحات  -

تاریخ انتشار 1994