Morphine Pharmacodynamics in Mechanically Ventilated Preterm Neonates Undergoing Endotracheal Suctioning
نویسندگان
چکیده
To date, morphine pharmacokinetics (PKs) are well quantified in neonates, but results about its efficacy are ambiguous. This work presents an analysis of a previously published study on pain measurements in mechanically ventilated preterm neonates who received either morphine or placebo to improve comfort during invasive ventilation. The research question was whether morphine reduces the pain associated with endotracheal or nasal suctioning before, during, and after suctioning. Because these neonates cannot verbalize their pain levels, pain was assessed on the basis of several validated pain measurement instruments (i.e., COMFORT-B, preterm infant pain profile [PIPP], Neonatal Infant Pain Scale (NIPS), and visual analogue scale (VAS)). The item response theory (IRT) was used to analyze the data in order for us to handle the data from multiple-item pain scores. The analysis showed an intra-individual relationship between morphine concentrations and pain reduction, as measured by COMFORT-B and VAS. However, the small magnitude of the morphine effect was not considered clinically relevant for this intervention in preterm neonates.
منابع مشابه
Morphine pharmacokinetics and pharmacodynamics in preterm and term neonates: secondary results from the NEOPAIN trial.
BACKGROUND Relationships between plasma morphine concentrations and neonatal responses to endotracheal tube (ETT) suctioning are unknown in preterm neonates. METHODS Ventilated preterm neonates (n=898) from 16 centres were randomly assigned to placebo (n=449) or morphine (n=449). After an i.v. loading dose (100 microg kg(-1)), morphine infusions [23-26 weeks postmenstrual age (PMA) 10 microg ...
متن کاملتأثیر فشردن قفسه سینه در زمان بازدم قبل از ساکشن داخل تراشه بر تبادل گازهای خون شریانی بیماران تحت تهویه مکانیکی
Background & Aim : Endotracheal suctioning is one of the most frequently used methods for airway clearance in patients under mechanical ventilation. Chest physiotherapy techniques such as expiratory rib cage compression before endotracheal suctioning can be used as a means to facilitate mobilizing and removing airway secretions and improving alveolar ventilation. This study was carried out to...
متن کاملThe Effects of Rib Cage Compression before endotracheal suctioning
Abstract Introduction: Accumulation of secretions in airways is a serious complication in intubated and mechanically ventilated patients. Tracheal suctioning which is done with the aim of secretion removal can be used in conjunction with physiotherapy for effective airway clearance and improving gas exchange. Objective: The aim of study was to determine the effects of rib cage compression befor...
متن کاملتاثیر فشردن قفسهی سینه در زمان بازدم قبل از ساکشن داخل تراشه بر اکسیژناسیون خون شریانی بیماران تحت تهویه مکانیکی
Background and Objective: Hypoxia is a major problem in patients undergoing ventilation due to the high bronchioles secretion. This study aimed to determine the effect of expiratory rib-cage compression prior to endotracheal suctioning on arterial blood oxygenation (SpO2) in patients undergoing mechanical ventilation. Materials and Methods: This clinical trial with a crossover design included 5...
متن کاملCommentary: Morrow B, Futter M, Argent A. (2006). Effect of endotracheal suction on lung dynamics in mechanically-ventilated paediatric patients.
Endotracheal suctioning is performed regularly in ventilated infants and children to remove obstructive secretions. The effect of suctioning on respiratory mechanics is not known. This study aimed to determine the immediate effect of endotracheal suctioning on dynamic lung compliance, tidal volume, and airway resistance in mechanically-ventilated paediatric patients by means of a prospective ob...
متن کامل