Variability of arterial blood gas values in stable patients in the ICU.

نویسندگان

  • S H Thorson
  • J J Marini
  • D J Pierson
  • L D Hudson
چکیده

To establish guidelines for the interpretation of changes in arterial blood gas (ABG) values, we studied 29 clinically stable ICU patients for spontaneous variability in PaO2, PaCO2 and pH. ABGs were sampled six times over a 50-minute period, during which all patients received a fixed FIO2 of 0.5 via endotracheal tube and underwent no therapeutic interventions. Each sample was analyzed in duplicate with careful attention to method of collection and measurement. The range separating the lowest and highest PaO2 varied from 1 to 45 mm Hg (16.2 +/- 10.9 mm Hg [mean +/- SD] ). For PaCO2 this range was from 1 to 8 mm Hg (3.0 +/- 1.9 mm Hg). Coefficient of variation for PaO2 and PaCO2 averaged 5.1 +/- 3.2 percent (mean +/- SD) and 3.0 +/- 1.5 percent respectively. pH varied within 0.03 +/- 0.02 units. Percentage change in PaO2 between sequential intrapatient samples averaged 5.3 +/- 2.8 percent (mean +/- SD) and 7.1 +/- 7.9 percent over ten- and 50-minute intervals, respectively. Various clinical features were analyzed by multiple regression analysis for their relation to PaO2 variation. Only leukocyte count and mean arterial oxygen content were statistically significant associations (p less than 0.05), but together explained less than 35 percent of the variation observed. Because considerable spontaneous variation occurs, even in stable patients, clinicians should base therapeutic decisions on trends in PaO2 values rather than on isolated changes interpreted without appropriate clinical correlation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

بررسی تاثیر وضعیت نیمه نشسته ومدت زمان آن برروی نتایج گازهای خون شریانی بیماران تحت تهویه مکانیکی بستری در ICU عمومی

Position changing with blood distribution to different portions of lung    can produce V/Q mismatch, and finally extend to oxygenation disruption.    Thus, if position changing  is done’ neglecting the patients’ pulmonary    problem types, not only does it fail to cause oxygenation improvement, but    it also induces gas exchange im...

متن کامل

بررسی تأثیر ماساژ پاها بر درصد اشباع اکسیژن شریانی بیماران مبتلا به سکته مغزی بستری در بخش I.C.U بیمارستان شهدای تجریش در سال 1382

Introduction: Intensive care unit is one of the most stressful wards for patients and it is estimated that 30 to70 percent of patients experience severe physiologic stress during admission. Some of the physiologic responses to stress include increase in metabolic rate with consequent increase in body temperature, increase in cardiac output and contraction power and subsequently increase in bloo...

متن کامل

Arterial blood gas and spirometry parameters affect the length of stay in hospitalized asthmatic patients

 Background: Asthma is a common condition in general medical practice, and it accounts for about 1% of all ambulatory hospital visits. Nowadays, hospitalization rates for asthma have actually been increased in some demographic subgroups despite recent advances in treatment. Understanding the underlying factors that contribute to hospitalization and especially duration of the hospitalizatio...

متن کامل

Renal Fractional Excretion of Sodium in Relation to Arterial Blood Gas and Spirometric Parameters in Chronic Obstructive Pulmonary Disease

Introduction: Arterial gas derangement could change urinary sodium excretion in Chronic Obstructive Pulmonary Disease (COPD) patients.There are very few and conflicting data in regards to the measurement of fractional excretion of sodium in COPD patients. The main aim of this study was to assess the relationship between renal fractional excretion of sodium(FeNa) with arterial blood gas and spir...

متن کامل

مقایسه اندازه‌گیری اشباع اکسیژن خون شریانی با پالس اکسی‌متری و نمونه خون شریانی در بیماران بخش مراقبت‌های ویژه قلبی

Background: Pulseoximetry is widely used in the critical care setting, currently used to guide therapeutic interventions. Few studies have evaluated the accuracy of SPO2 (puls-eoximetry oxygen saturation) in intensive care unit after cardiac surgery. Our objective was to compare pulseoximetry with arterial oxygen saturation (SaO2) during clinical routine in such patients, and to examine the eff...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Chest

دوره 84 1  شماره 

صفحات  -

تاریخ انتشار 1983