BACKGROUND The acetabular component has remained the weakest link in hip arthroplasty regarding achievement of long-term survival. Primary fixation is a prerequisite for long-term performance. For this reason, we investigated the stability of a unique cementless titanium-coated elastic monoblock socket and the influence of supplementary screw fixation. PATIENT AND METHODS During 2006-2008, we performed a randomized controlled trial on 37 patients (mean age 63 years (SD 7), 22 females) in whom we implanted a cementless press-fit socket. The socket was implanted with additional screw fixation (group A, n = 19) and without additional screw fixation (group B, n = 18). Using radiostereometric analysis with a 2-year follow-up, we determined the stability of the socket. Clinically relevant migration was defined as > 1 mm translation and > 2º rotation. Clinical scores were determined. RESULTS The sockets without screw fixation showed a statistically significantly higher proximal translation compared to the socket with additional screw fixation. However, this higher migration was below the clinically relevant threshold. The numbers of migratory sockets were not significantly different between groups. After the 2-year follow-up, there were no clinically relevant differences between groups A and B regarding the clinical scores. 1 patient dropped out of the study. In the others, no sockets were revised. INTERPRETATION We found that additional screw fixation is not necessary to achieve stability of the cementless press-fit elastic RM socket. We saw no postoperative benefit or clinical effect of additional screw fixation.
منابع مشابه
Cancellous and cortical bone mineral density around an elastic press-fit socket in total hip arthroplasty
Background and purpose - The acetabular component has remained the weakest link in hip arthroplasty for achievement of long-term survival. One of the possible explanatory factors for acetabular failure has been acetabular stress shielding. For this, we investigated the effects of a cementless elastic socket on acetabular bone mineral density (BMD). Patients and methods - During 2008-2009, we pe...
متن کاملCementless hemispheric porous-coated sockets implanted with press-fit technique without screws: average ten-year follow-up.
BACKGROUND Press-fit implantation of a porous-coated hemispheric acetabular component without screws is an option for primary total hip replacement. The purpose of the present study was to evaluate the results of this technique after an average duration of follow-up of ten years to determine if there was any loss of fixation or increase in osteolysis over time. METHODS From June 1988 to Novem...
متن کاملMigration pattern of cementless press fit cups in the presence of stabilizing screws in total hip arthroplasty
The aim of this study was to evaluate the initial acetabular implant stability and late acetabular implant migration in press fit cups combined with screw fixation of the acetabular component in order to answer the question whether screws are necessary for the fixation of the acetabular component in cementless primary total hip arthroplasty. One hundred and seven hips were available for follow-...
متن کاملZurich cementless hip prosthesis and other modern trends in orthopedic surgery
New concepts disclaim the use of cementum. They either use press fit or screw fixation to anchor the implants.The most important characteristics of the Zurich Cementless hip prosthesis, developed between 1993 and 2001, is avoidance of the coupling effect of the medial and lateral femoral cortices, and stress shielding due to compliance mismatch. The stem is fastened to the medial cortex with 4 ...
متن کاملResults of the cementless Plasmacup in revision total hip arthroplasty: a retrospective study of 72 cases with an average follow-up of eight years
BACKGROUND There are multiple revision implant systems currently available for socket revision in revision total hip arthroplasty. Up until now, not all of these systems have been followed up with regards to their long-term use as a revision implantation.For the first time, this study presents the hemispherical porous-coated socket Plasmacup SC, produced by Aesculap, Tuttlingen, Germany, and th...