Flap complications in our learning curve of laser in situ keratomileusis using the Hansatome microkeratome.
نویسندگان
چکیده
PURPOSE To determine the incidence and the type of flap complications in our initial series of eyes undergoing laser in situ keratomileusis and the impact of microkeratome-related complications on best spectacle-corrected visual acuity. METHODS We reviewed the charts of the 630 consecutive eyes operated in the Refractive Surgery Department of Cerrahpasa Medical School, University of Istanbul, Turkey using the Hansatome microkeratome and the Summit, SVS Apex Plus excimer laser between March 1998 and November 1999. The mean follow-up was 12.6 months. RESULTS The incidence of total flap complications was 19.8%. Flap folds (5%) were the most common complication. The incidence of epithelial ingrowth was 3.3%. Diffuse lamellar keratitis was encountered in 20 cases (3.17%). Displaced flaps were seen shortly after the procedure in 8 eyes (1.26%) and repositioned immediately. Improper keratectomy occurred in 14 eyes (2.2%) and incomplete keratectomy in four procedures (0.63%). The presence of interface debris and hemorrhage was each 1.9%. We observed one interface abscess, which was culture-negative and cured with fortified antibiotics, and one free flap. CONCLUSIONS Although the LASIK procedure with the Hansatome had an easy learning curve without any of the serious complications that frequently occur in this phase, we still observed flap related complications that affected visual outcome.
منابع مشابه
Lower intraoperative flap complication rate with the Hansatome microkeratome compared to the Automated Corneal Shaper.
PURPOSE The purpose of this study was to retrospectively compare the incidence of intraoperative flap complications, such as partial flaps, donut-shaped flaps, central corneal cuts, and complete caps with the Hansatome and Automated Corneal Shaper (ACS) microkeratomes. METHODS All laser in situ keratomileusis (LASIK) procedures performed by a single surgeon with the Hansatome or Automated Cor...
متن کاملIn vivo corneal confocal microscopy comparison of intralase femtosecond laser and mechanical microkeratome for laser in situ keratomileusis.
PURPOSE To assess and compare corneal modifications induced by IntraLase PulsionFS femtosecond laser and mechanical microkeratome Hansatome for laser in situ keratomileusis (LASIK) using the new-generation Heidelberg Retina Tomograph II (HRT II)/Rostock Cornea Module confocal microscope. METHODS In this case-control study, 24 eyes of 12 patients were examined with the HRT II in the follow-up ...
متن کاملFemtosecond laser versus mechanical keratome flaps in wavefront-guided laser in situ keratomileusis: prospective contralateral eye study.
PURPOSE To compare the outcomes of wavefront-guided laser in situ keratomileusis (LASIK) performed using the IntraLase femtosecond laser with the outcomes using the Hansatome mechanical microkeratome. SETTING Private clinic, Overland Park, Kansas, USA. METHODS In a prospective contralateral-eye study performed under institutional review board supervision, 51 consecutive patients (102 eyes) ...
متن کاملCLINICAL SCIENCE Posterior corneal topographic changes after partial flap during laser in situ keratomileusis
Aim: To study the posterior corneal topographic changes in eyes with partial flaps during laser assisted in situ keratomileusis (LASIK). Methods: Case records of 16 patients, who had partial flap in one eye during LASIK (group 1) and uncomplicated surgery in the other eye (group 2), were studied. Following occurrence of partial flap intraoperatively, laser ablation was abandoned in all the eyes...
متن کاملFlap complication rate for two microkeratomes.
To the Editor: The article “Lower Intraoperative Flap Complication Rate with the Hansatome Microkeratome Compared to the Automated Corneal Shaper” (Walker MB, Wilson SE. J Refract Surg 2000;16:79-82) concludes that the Hansatome is less likely to have intraoperative flap complications than the Automated Corneal Shaper (ACS). This may be true but the methods used in the study do not allow this c...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- European journal of ophthalmology
دوره 11 4 شماره
صفحات -
تاریخ انتشار 2001