Differential Pulse Voltammetric Method for 4-Nonylphenol Determination in Water Samples

نویسندگان

  • MIHAELA BULEANDRA
  • ANDREEA ALEXANDRA RABINCA
  • ELENA CORNELIA MITRAN
  • ANTON ALEXANDRU CIUCU
چکیده

A novel assay for the electrochemical detection of 4-nonylphenol (4-NP) based on carbon nanotubes modified screen-printed carbon electrodes (CNTs-SPCEs) has been investigated. The electrochemical behavior of the modified SPCEs and the mechanism of the oxidation of NP were investigated using cyclic voltammetry. The differential pulse voltammetry parameters were optimized for quantitative determination of 4nonylphenol. A detection limit of 9.95·10-6 mol·L-1 was obtained for 4-nonylphenol using its oxidation signal at +0.25 V. The disposable sensor showed good performance and was applied for the determination of 4nonylphenol in tap water with satisfactory results.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Disposable carbon electrodes as an alternative for the direct voltammetric determination of alkyl phenols from water samples

Disposable sensors based on a pencil graphite electrode were described for detection of alkyl phenols. The performances of the disposable bare pencil graphite electrode (PGE) and PGE modified with carbon nanotubes, regarding the cyclic and differential pulse voltammetric determination of 4-nonylphenol, 4-octylphenol, and 4-tert-octylphenol, were compared. Some experimental variables of the elec...

متن کامل

Simultaneous Adsorptive Stripping Differential Pulse Voltammetric Measurements of Trace Lead, Cadmium and Nickel in the Presence of 2-aminobenzoic Acid

In this study, 2-aminobenzoic acid (ABA) has been used as complexing ligand for simultaneousdetermination of metal ions by adsorptive cathodic stripping voltammetry (AdCSV), for the firsttime. Thus, a selective and sensitive procedure was presented for simultaneous determination oflead, cadmium and nickel using ABA and differential pulse-adsorptive cathodic strippingvolt...

متن کامل

Voltammetric Determination of Copper Ion in Water Samples Using a Drop Casted Biopolymer

Poly-dopamine, inspired by biopolymers of mussels, is an adhesive catecholamine possessing low cytotoxicity and very good biocompatibility. In the present study, poly-dopamine nanoparticles (PDNP), as a biopolymer, were synthesized and characterized using FTIR spectroscopy, scanning electron microscopy and electrochemical methods. The drop casted PDNPs at the surface of carbon paste electrode (...

متن کامل

Silica Nanoparticles Modified Carbon Paste Electrode as a Voltammetric Sensor for Determination of Diclofenac

The present study describes the use of a new carbon paste electrode modified by means of Silica nanoparticles prepared by a simple and rapid procedure for the determination of sodium diclofenac (DCF). Moreover, the present study focuses on the characterization of electrochemical impedance spectroscopy (EIS) and scanning electron microscopy (SEM) of the prepared Silica NPs-CPE. In this work, The...

متن کامل

Voltammetric Determination of Sulfadoxine and Its Application in Pharmaceuticals and Urine Samples

The voltammetric behaviour of Sulfadoxine (SDN) was studied at a glassy carbon electrode in 0.2 M phosphate buffer solutions using cyclic, differential-pulse (DPV) and square wave voltammetry (SWV). The dependence of the current on pH, concentration, and scan rate was investigated to optimize the experimental conditions for the determination of SDN. The oxidation process was shown to be diffusi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016