Validation of the Vivago

نویسندگان

  • Jérémy Vanhelst
  • Rémy Hurdiel
  • Jacques Mikulovic
  • Gilles Bui-Xuân
  • Paul Fardy
  • Denis Theunynck
  • Laurent Béghin
چکیده

Background: Most accelerometers are worn around the waist (hip or lower back) to assess habitual physical activity. Wrist-worn accelerometers may be an alternative to the waist-worn monitors and may improve compliance in studies with prolonged wear. The aim of this study was to validate the Vivago ® Wrist-Worn Accelerometer at various intensities of physical activity (PA) in adults. Methods: Twenty-one healthy adults aged 20–34 years were recruited for the study. Accelerometer data and oxygen uptake (VO2) were measured at sedentary, light, moderate and vigorous levels of PA. Results: Activity categories and accelerometer counts were: sedentary, 0–15 counts min –1 ; light, 16–40 counts min –1 ; moderate, 41–85 counts min –1 ; and vigorous activity, > 85 counts min –1 . ANOVA repeated measures was used to determine the relationship between accelerometry data output and oxygen consumption (r = .89; p < .001). The Bland and Altman method showed good agreement in the assessment of energy expenditure between the indirect calorimetry and the data obtained by the accelerometer. Conclusions: Results of the study suggest that the Vivago ® wrist-worn accelerometer is a valid measure of PA at varying levels of intensity. The study has also defined threshold values at four intensities and hence the Vivago ® accelerometer may be used to quantify PA in free living conditions among adults. This device has possible application in treating a variety of important health concerns.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Validation of the Vivago Wrist-Worn accelerometer in the assessment of physical activity

BACKGROUND Most accelerometers are worn around the waist (hip or lower back) to assess habitual physical activity. Wrist-worn accelerometers may be an alternative to the waist-worn monitors and may improve compliance in studies with prolonged wear. The aim of this study was to validate the Vivago® Wrist-Worn Accelerometer at various intensities of physical activity (PA) in adults. METHODS Twe...

متن کامل

Circadian activity rhythm in demented and non-demented nursing-home residents measured by telemetric actigraphy.

There is a need to develop unobtrusive methods for long-term monitoring of sleep/wake and circadian activity patterns in the elderly both in nursing homes and at home settings as sleep is important for health and well-being. The IST Vivago WristCare is an active social alarm system, which provides continuous telemetric monitoring of the user's activity. We examined how the activity signal measu...

متن کامل

Technical variability of the Vivago® wrist-worn accelerometer.

The aim was to assess the technical variability of a new wrist-worn accelerometer under controlled conditions with a shaker device and during normal daily physical activities (PAs). In the first experiment, 10 wrist-worn accelerometers (Vivago(®) Wellness, Paris, France) were attached to the shaker device. Variability was tested at five shaking frequencies (1.1, 2.1, 3.1, 4.1, and 10 Hz) for 10...

متن کامل

Overview of the validation procedures for a vaccine production: from R&D level to the pre-qualification stage

Just like any other process, vaccine manufacturing procedures are defined as a series of interrelated functions and activities using a variety of specified actions and equipment designed to produce a defined product. To assure the reproducibility and consistency of such processes, they must be carried out using validated equipment and under the established procedures that meet all the acceptanc...

متن کامل

Customer Validation in Cross-Dock

Considering the importance of validation of customers in the cross-dock and since this is one of the problems of implementing cross-dock system in Iran, this study attempted to extract customer validation criteria. The purpose of the research is to eliminate the distrust of distributors in receiving the funds of the sent items and the statistical sample of this research is the experts of the sy...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012