Validating MRI Field Homogeneity Correction Using Image Information Measures
نویسندگان
چکیده
For image analysis techniques to be of utility in medical diagnosis systems it is necessary to be able to perform quality control over the results they produce. Input data must conform to the assumptions within the algorithm if useful results are to be achieved. Automation of this process is essential if vision algorithms are to form components in analysis systems. In this paper we present a technique to validate the correction of field inhomogeneity in MR images. The initial intention was to use information measures to check the improvement due to correction. However, it will be shown that the standard log entropy calculation for information measurement does not have the required properties, specifically grey-level scale invariance. We present an alternative, scaleinvariant information measure derived using conventional likelihood approaches, that can be applied as an absolute measure of information content. We show this technique in use for the validation of our existing coil correction method [9].
منابع مشابه
Validating MRI Field Homogeneity Correction Using Image
For image analysis techniques to be of utility in medical diagnosis systems it is necessary to be able to perform quality control over the results they produce. Input data must conform to the assumptions within the algorithm if useful results are to be achieved. Automation of this process is essential if vision algorithms are to form components in analysis systems. In this paper we present a te...
متن کاملAssessment of the Characteristics of MRI Coils in Terms of RF Non-Homogeneity Using Routine Spin Echo Sequences
Introduction: One of the major causes of image non-uniformity in MRI is due to the existence of non-homogeneity in RF receive and transmit. This can be the most effective source of error in quantitative studies in MRI imaging. Part of this non-homogeneity demonstrates the characteristics of RF coil and part of it is due to the interaction of RF field with the material being imaged...
متن کاملSecurity, confidentiality, and privacy of information in the field of health with data EPR embedding in medical MRI images based on HVS model
the development of new technology and modern equipment has led to the development of telemedicine systems. As a result, there are dangers such as publishing patient information and intentionally or unintentionally, medical information. The forensic organization, as one of the powerful arms of the judiciary, pursues important cases in the medical and psychiatric commissions to take steps to rea...
متن کاملImproving robustness and reliability of phase-sensitive fMRI analysis using temporal off-resonance alignment of single-echo timeseries (TOAST)
Echo Planar Imaging (EPI), often utilized in functional MRI (fMRI) experiments, is well known for its vulnerability to inconsistencies in the static magnetic field (B(0)). Correction for these field inhomogeneities usually involves measuring the magnetic field at a single time point, and using this static information to correct a series of images collected over the course of one or multiple exp...
متن کاملCorrection of Intensity In-Homogeneity of MR Image Based on Average Median Intensity Value Method
The Magnetic Resonance Image (MRI) may be valuable techniques for learning the structural property of the human brain. However, the reproducibility of imaging results, that arises from swish intensity variation happens the entirety MR image, named as Intensity in-homogeneity or nonuniformity. The intensity in-homogeneity may be a hurdles encountered in human and computer interpretations and ana...
متن کامل