Global contour processing in amblyopia

نویسندگان

  • Dennis M. Levi
  • Cong Yu
  • Shu-Guang Kuai
  • Elizabeth Rislove
چکیده

The purpose of the experiments described here was to investigate global image processing using methods that require global processing while eliminating or compensating for low level abnormalities: visibility, shape perception and positional uncertainty. In order to accomplish this we used a closed figure made up of Gabor patches either in noise or on a blank field. The stimuli were circular or elliptical contours, formed by N equally spaced Gabor patches. We performed two separate experiments: In one experiment we fixed N and varied the aspect ratio using a staircase to determine the threshold aspect ratio; in the second experiment we held the aspect ratio constant (at twice the threshold aspect ratio) and varied N in order to measure the threshold number of elements required to judge the shape. Our results confirm and extend previous studies showing that humans with naturally occurring amblyopia show deficits in contour processing. Our results show that the deficits depend strongly on spatial scale (target size and spatial frequency). The deficit in global contour processing is substantially greater in noise (where contour-linking is required) than on a blank field. The magnitude of the deficits is modest when low-level deficits (reduced visibility, increased positional uncertainty, and abnormal shape perception) are minimized, and does not seem to depend much on acuity, crowding or stereoacuity. The residual deficits reported here cannot be simply ascribed to reduced visibility or increased positional uncertainty, and we therefore conclude that these are genuine deficits in global contour segregation and integration.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The global shape detection deficit in strabismic amblyopia: Contribution of local orientation and position

We extended a previous study (Hess et al. (1999). A deficit in strabismic amblyopia for global shape detection. Vision Research, 39, 901-914) where it was claimed that strabismic amblyopes exhibit a deficit for the detection of continuous radial frequency patterns, a task that is thought to involve global processing and in particular, a contribution of extra-striate area V4. We confirm this pre...

متن کامل

Altered global shape discrimination in deprivation amblyopia

To assess the effect of deprivation amblyopia on global shape discrimination, sensitivity to radial deformation of circular patterns was assessed in patients treated for congenital (N=7) or developmental (N=1) cataracts. Elevation in radial deformation threshold was dependent on circular contour frequency and the depth of amblyopia. Analysis of thresholds expressed as Weber fractions indicated ...

متن کامل

Global processing in amblyopia: a review

Amblyopia is a neurodevelopmental disorder of the visual system that is associated with disrupted binocular vision during early childhood. There is evidence that the effects of amblyopia extend beyond the primary visual cortex to regions of the dorsal and ventral extra-striate visual cortex involved in visual integration. Here, we review the current literature on global processing deficits in o...

متن کامل

Contour integration in anisometropic amblyopia

Contour integration was measured in a group of anisometropic amblyopes to test the idea recently put forward that positional uncertainty sets a fundamental limit to contour integration in amblyopia. Anisometropic amblyopia, unlike strabismic amblyopia, has little or no positional uncertainty once the initial filtering loss has been taken into account. Therefore, according to the explanation put...

متن کامل

A new test of contour integration deficits in patients with a history of disrupted binocular experience during visual development

Previous studies have suggested that the integration of orientation information across space is impaired in amblyopia. We developed a method for quantifying orientation-domain processing using a test format that is suitable for clinical application. The test comprises a graded series of cards where each card includes a closed path (contour) of high contrast Gabor signals embedded in a random ba...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Vision Research

دوره 47  شماره 

صفحات  -

تاریخ انتشار 2007