Vascular complications following intra-aortic balloon pump implantation: an updated review
نویسندگان
چکیده
BACKGROUND The use of the intra-aortic balloon pump (IABP) as a support device remains controversial due to the fact that a number of studies have shown no benefit in end mortality whilst using this device. One of the reasons for this could be the increase in vascular complications when using the pump. Therefore, the aim of the present review was to assess the current literature available with regards to IABP vascular complications during the clinical situation. METHODS A literature search was performed, searching for IABP complications in adult human studies between 1990 and 2016. RESULTS A total of 20 reports were identified as fitting the criteria of this study. The majority of vascular complications were limb ischemia, bleeding or mesenteric ischemia. The overall incidence of vascular complications ranged from 0.94% to 31.1%. Diabetes, peripheral vascular disease and hypertension, as well as smoking were all identified as risk factors for complications following IABP. Furthermore, studies supported the use of sheathless balloon insertion to reduce the risk of complications. CONCLUSION Major vascular complications, including limb and mesenteric ischemia as well as bleeding and hemorrhage, have been associated with IABP. However, the incidence of these complications was generally low. Further studies are still required to truly understand the risk/benefit associated with the use of IABP.
منابع مشابه
The Evaluation of Survival in Patients Who Need Intra Aortic Balloon Pump (IABP) after Cardiac Surgery
Introduction: Insome cases, assist devices are required to ensure an adequate cardiac output after cardiac surgery. Intra-aortic balloon pump (IABP) is the most commonly used cardiac assist device, which provides first-line support for patients with heart failure. The aim of this study was to determine factors affecting the mortality rate of patients receiving IABP. Materials & Methods: In thi...
متن کاملIntra aortic balloon pump: literature review of risk factors related to complications of the intraaortic balloon pump
The increasing use of the intra aortic balloon pump is attributed to the relatively easy percutaneous insertion and the low threshold of use over the past few years, especially in elderly patients with multi-vessel diseases and an affected ejection fraction.Unfortunately, the clinical assessment of the complications associated to the use of this supporting device, underestimates the frequency o...
متن کاملSafety and Efficacy of the StarClose Vascular Closure System following 8-Fr Sheath Placement for Intra-Aortic Balloon Pump: A Single-Center Analysis of 42 Consecutive Patients
OBJECTIVE To assess the safety and efficacy of the StarClose device following intra-aortic balloon pump (IABP) counterpulsation using 8-Fr femoral sheaths. SUBJECTS AND METHODS From June 2008 to August 2012, 42 consecutive patients who received IABP implantation via common femoral artery (CFA) punctures with an 8-Fr sheath (which were then sealed with the StarClose Vascular Closure System at ...
متن کاملStaphylococcus aureus bacteremia associated with intra-aortic balloon pumps.
To the Editor: Since its first clinical use in the late 1960s, intra-aortic balloon pump counterpulsation has been a significant means of supporting an inadequate myocardium.' The use of an intra-aortic balloon pump has increased greatly preceding open heart surgery for cardiogenic shock and left ventricular failure. Additional indications include other conditions such as unstable angina refrac...
متن کاملManagement of intra-aortic balloon pumps.
Intra-aortic balloon pumps (IABPs) continue to be the most widely used cardiac support devices with an annual estimate of 200 000 IABPs placed worldwide. IABPs enhance myocardial function by maximizing oxygen supply and minimizing oxygen demand. The use of IABPs is not without risk, with major vascular injury, ischemia, and infection being the most common complications, especially in high-risk ...
متن کامل