New technique: repositioning of dislodged atrial pacing lead with a specially designed urological basket.
نویسندگان
چکیده
The rate of dislodgement of atrial pacing leads is approximately 3%. To solve this problem, reoperation and repositioning of these leads is one of the solutions. Some operators have reported repositioning these leads with snare systems or deflectable catheters. In this communication, we present a new method using a specially designed urological basket to solve this problem.
منابع مشابه
Spontaneous reattachment of a dislodged atrial lead.
Acute lead dislodgment is a complication that should be managed immediately. Spontaneous reattachment of a dislodged atrial pacing lead has never been reported before. This case report describes a lucky patient whose atrial lead spontaneously gained a new functioning position after dislodgment from its initial implantation site.
متن کاملComplex percutaneous extraction of a 15-year-old atrial lead dislodged into the subclavian vein
We present a case of a 50-year-old patient with DDD pacing failure who underwent atrial lead extraction. The lead was implanted 15 years ago, and 4 months ago it dislodged into the subclavian vein following a fracture. The lead was removed via the femoral vein approach using a Cook Medical device (Byrd Femoral Workstation, Dotter basket) and pigtail catheter.
متن کاملSuccessful percutaneous repositioning of a dislodged atrial pacemaker lead with a deflectable catheter.
A 67-year-old male patient with ischemic dilated cardiomyopathy underwent implantation of an implantable cardioverter-defibrillator with cardiac resynchronization therapy about one month ago. The implantation process was successful and the patient was discharged in good condition. At the routine first month follow-up, pacemaker analysis revealed that there was no atrial pacing and sensing, alth...
متن کاملPercutaneous right atrial pacemaker lead repositioning using a regular deflectable ablation catheter
Lead dislocation is one of the most undesired complications of permanent pacemaker implantation. The rate of dislodgement of atrial pacing leads is nearly 3% [1]. Reopening the pacemaker pocket and repositioning the lead is the most commonly used technique for correcting dislocations which occur in the early period after implantation. However, this increases the risk of pocket infection and inc...
متن کاملA novel approach for endocardial resynchronization therapy: initial experience with transapical implantation of the left ventricular lead.
BACKGROUND Coronary sinus lead placement for transvenous left ventricular (LV) pacing in cardiac resynchronization therapy (CRT) has a significant failure rate at implant and a considerable dislocation rate during follow-up. For these patients epicardial pacing lead implantation is the most frequently used alternative. Recent data support endocardial lead implantation through the atrial septum ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology
دوره 9 2 شماره
صفحات -
تاریخ انتشار 2007