Optimisation of X-ray micro-tomography for the low-dose analysis of highly-dosed gels

نویسنده

  • P M Jenneson
چکیده

An X-ray micro-tomography system has been designed that is optimised for low dose imaging of radiation sensitive polymer gels. The scanner is based on a third-generation cone-beam X-ray CT scanner. A mini-focus X-ray source (Oxford XTF5011 or an Oxford series 1500) is used in conjunction with a 100mm diameter X-ray image intensifier (Hamamatsu C7336). The sample may be rotated and moved perpendicular to the beam axis. A schematic view of the system is shown in figure 1. The XTF5011 X-ray source has a focal spot diameter of 100μm, has a silver target, and is operated at 50 kVp, 0.5 mA and the series 1500 source has a focal spot diameter of 33 μm, has a tungsten target, and is operated at 80 kVp, 0.25 mA. The polychromatic source from the XTF5011 X-ray source is filtered using 2 mm of aluminium and 50 μm of palladium giving a “quasi-monochromatic” spectrum centred about the 22 keV silver Kα characteristic peak. Institute of Physics Publishing Journal of Physics: Conference Series 3 (2004) 257–260 doi:10.1088/1742-6596/3/1/041 Third International Conference on Radiotherapy Gel Dosimetry

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Impact of Photon Spectra on the Sensitivity of Polymer Gel Dosimetry by X-Ray Computed Tomography

Introduction: The purpose of the current study was to investigate the effect of X-ray spectra on the sensitivity of a polymer gel dosimeter imaged with a conventional computed tomography (CT) scanner. Material and Methods: The whole process of CT imaging of an irradiated polymer gel was simulated by MCNPX Monte Carlo (MC) code. The imaging of polyacrylamide gel was accomplished by means of a co...

متن کامل

Introducing a novel Polyvinyl chloride/Tungsten composites for shielding against gamma and X-ray radiations

Introduction: This study introduces a novel polyvinyl chloride (PVC)/tungsten composites with characterization of their shielding properties by employing different techniques. Methods: The PVC/tungsten composites were produced by employing various weight fractions of tungsten micro-particles including 0, 20, and 40 % wt via melt blending method. In the next st...

متن کامل

Investigation of dosimetric characteristic of NIPAM polymer gel using x-ray CT

Introduction: Polymer gel dosimeters contain chemical materials sensitive to the radiation which are polymerized by the radiation as a function of absorbed dose. So information of spatial dose distribution can be extracted by imaging from irradiated gel. Among imaging techniques, computed tomography (CT) poses as an attractive method because of practical advantages such as acce...

متن کامل

Patient doses from X-ray computed tomography examinations by a single-array detector unit: Axial versus spiral mode

Background: X-ray computed tomography (CT) examinations deliver a significant amount of radiation doses to patients comparing to conventional radiography examinations. The objective of the current study was to analyze and investigate the average patient received dose from axial and spiral CT exams in a medical imaging center. Material and Methods: In this study, the patient imaging tec...

متن کامل

Optical Characterization of NIPAM and PAGAT Polymer Gels for Radiation Dosimetry

Introduction The purpose of the current study was to determine optical sensitivity of N-isopropyl acrylamide NIPAM and polyacrylamide gelatin and tetrakis hydroxymethyl phosphoniun chloride (PAGAT) polymer gels for different wavelength of visible light spectrum applied in optical computed tomography method. Materials and Methods NIPAM and PAGAT polymer gels with conventional formulations used f...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2004