A wire-loop technique for implantation of an iliac branched device in a patient with previous surgery for a ruptured abdominal aortic aneurysm.

نویسندگان

  • Umberto Marcello Bracale
  • Donatella Narese
  • Gaetano Vitale
  • Franco Maglione
  • Pietro Orlando Conti
  • Guido Bajardi
چکیده

We described a modified technique for implanting a bridging stent-graft into an iliac branched device. A 79-year-old male who had received aortobiiliac synthetic graft surgery for a ruptured abdominal aortic aneurysm six months earlier was admitted to our unit for treatment of a left common iliac aneurysm involving the origin of the hypogastric artery. A standard technique was unsuccessful at implanting the bridging stent-graft, and therefore a wire-loop guidewire over the graft bifurcation was used to stabilize the contralateral sheaths and to complete the implantation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Management of anesthesia in a patient with ruptured abdominal aortic aneurysm: A case report

Introduction: Abdominal aortic aneurysm is a multifactorial condition which associated with aging and atherosclerosis. During aneurysm surgery, hypotension after aortic clamp removing occure commonly that require specific treatments. This case report showes administration of blood and hemodynamic control methods after aortic unclumping during aortic aneurysm surgery. Patient: A 75–years-o...

متن کامل

Successful endovascular coiling of a ruptured internal iliac artery aneurysm: a case report

Ruptured internal iliac artery aneurysms (IIAA) are extremely rare, and the repair can be challenging. This case reports described an 83-year-old patient who presented at our Emergency Department with acute abdominal pain based on a ruptured IIAA. He refused open repair and only wanted to be treated as minimally invasive as possible. Therefore endovascular embolization of the IIAA was performed...

متن کامل

Renal insufficiency after infrarenal abdominal aortic aneurysm reconstruction: An analysis of this risk factor in 45 patients

 Abstract Background: Renal insufficiency is a potential complication after infrarenal abdominal aortic aneurysm repair and is a significant risk factor for postoperative mortality and morbidity. The aim of this study was to analyze the effect of this risk factor, before and during operation. Methods: In this prospective study, between 2003 and 2006, 45 patients underwent repair of an infrarena...

متن کامل

Endovascular aneurysm repair in emergent ruptured abdominal aortic aneurysm with a ‘real’ hostile neck and severely tortuous iliac artery of an elderly patient

BACKGROUND Endovascular aneurysm repair (EVAR) has been a revolutionary development in the treatment of abdominal aortic aneurysms (AAAs). Meanwhile, unfavorable anatomy of the aneurysm has always been a challenge to vascular surgeons, and the application of EVAR in emergent and elderly patients are still in dispute. CASE PRESENTATION A 79-year-old woman presented as an emergency of abdominal...

متن کامل

Renoprotective potential of exogen erythropoietin on experimental ruptured abdominal aortic aneurysm model: An animal study

Objective(s): The aim of this study is to investigate the renoprotective effect of erythropoietin (EPO) on hypovolemic shock and ischemia/reperfusion (IR) injury on kidneys as end-organs in an experimentally-created ruptured abdominal aortic aneurysm (rAAA) model.Materials and Methods: Thirty anesthetized Sprague-Dawley male rats were ra...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Diagnostic and interventional radiology

دوره 19 1  شماره 

صفحات  -

تاریخ انتشار 2013