IVF outcome is optimized when embryos are replaced between 5 and 15 mm from the fundal endometrial surface: a prospective analysis on 1184 IVF cycles

نویسندگان

  • Valentina Rovei
  • Paola Dalmasso
  • Gianluca Gennarelli
  • Teresa Lantieri
  • Gemma Basso
  • Chiara Benedetto
  • Alberto Revelli
چکیده

BACKGROUND Some data suggest that the results of human in vitro fertilization (IVF) may be affected by the site of the uterine cavity where embryos are released. It is not yet clear if there is an optimal range of embryo-fundus distance (EFD) within which embryos should be transferred to optimize IVF outcome. METHODS The present study included 1184 patients undergoing a blind, clinical-touch ET of 1-2 fresh embryos loaded in a soft catheter with a low amount of culture medium. We measured the EFD using transvaginal US performed immediately after ET, with the aim to assess (a) if EFD affects pregnancy and implantation rates, and (b) if an optimal EFD range can be identified. RESULTS Despite comparable patients' clinical characteristics, embryo morphological quality, and endometrial thickness, an EFD between 5 and 15 mm allowed to obtain significantly higher pregnancy and implantation rates than an EFD above 15 mm. The abortion rate was much higher (although not significantly) when EFD was below 5 mm than when it was between 5 and 15 mm. Combined together, these results produced an overall higher ongoing pregnancy rate in the group of patients whose embryos were released between 5 and 15 mm from the fundal endometrial surface. CONCLUSIONS The site at which embryos are released affects IVF outcome and an optimal EFD range exists; this observations suggest that US-guided ET could be advantageous vs. clinical-touch ET, as it allows to be more accurate in releasing embryos within the optimal EFD range.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

P-183: Evaluation of Endometrial Thickness on The Day of HCG Administration on IVF Outcome

Background: Despite recent technical improvement in assisted reproductive techniques (ART), the implantation rate per embryo still remains low (15%). The aim of the study is to determine whether the failure of IVF cycle is associated with endometrial thickness on the day of HCG (human chorionic gonadotropin) administration. Materials and Methods: Endometrial thickness of two hundred and seven p...

متن کامل

A Comparison of Outcomes from IVF Cycles Stimulated with either Recombinant Luteinizing Hormone or Human Menopausal Gonadotropins in Subjects Treated with Long Gonadotropin Releasing Hormone Agonist Protocols, a Retrospective Analysis.

Objective The objective of this study is to compare rates of pregnancy and IVF parameters in subjects who were stimulated with follicle stimulating hormone (FSH) plus either recombinant human luteinizing hormone (r-LH) or human menopausal gonadotropins (hMG), in long gonadotropin releasing hormone (GnRH) agonist IVF protocols. MaterialsAndMethods This is a cohort study of patients undergoing IV...

متن کامل

The Pregnancy Outcome of Singletons in IVF/ ICSI Cycles: A Cross-Sectional Study

Background The aim of this study was to compare prenatal outcome of intra cytoplasmic sperm injection (ICSI) pregnancies with pregnancies obtained through in vitro fertilization (IVF). MaterialsAndMethods Retrospectively 532 pregnancies of ART cycles were assessed during 1999-2000. The main outcome measured including abortions, ectopic pregnancies, prematurity, low birth weight, cesarean sectio...

متن کامل

P-228: Low Dose HCG Adjunct to r-hFSH/GnRH Antagonist for Controlled Ovarian Stimulation in Assisted Reproductive Technology: A Prospective and Randomized Trial

Background: Deep suppression of LH in GnRH antagonist cycles may have detrimental effect on reproductive out come. It was hypnotized that adding LH activity via the administration of low dose HCG in late follicular phase shortened the duration of stimulation, decreased consumption of gonadotropin and increased estrogen levels. This study was designed to evaluate the effect of adding low dose HC...

متن کامل

Absolute position versus relative position in embryo transfer: a randomized controlled trial

BACKGROUND Meta-analysis revealed that embryo placement 20 mm from the fundal endometrial surface resulted in higher pregnancy rate, ongoing pregnancy rate, and live birth rate compared with placement 10 mm from the fundal endometrial surface. Pregnancy and implantation rates according to relative position were higher when the catheter tip was positioned close to the middle of the endometrial c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2013