Prostate Cryotherapy Monitoring Using Vibroacoustography: Preliminary Results of an Ex Vivo Study and Technical Feasibility
نویسندگان
چکیده
The objective of this research is to prospectively evaluate the feasibility of vibroacoustography (VA) imaging in monitoring prostate cryotherapy in an ex vivo model. Baseline scanning of an excised human prostate is accomplished by a VA system apparatus in a tank of degassed water. Alcohol and dry ice mixture are used to freeze two prostate tissue samples. The frozen prostates are subsequently placed within the water tank at 27 degrees C and rescanned. VA images were acquired at prescribed time intervals to characterize the acoustic properties of the partially frozen tissue. The frozen prostate tissue appears in the images as hypoemitting signal. Once the tissue thaws, previously frozen regions show coarser texture than prior to freezing. The margin of the frozen tissue is delineated with a well-defined rim. The thawed cryolesions show a different contrast compared with normal unfrozen prostate. In conclusion, this pilot study shows that VA produces clear images of a frozen prostate at different temperature stages. The frozen tissue appears as a uniform region with well-defined borders that are readily identified. These characteristic images should allow safer and more efficient application of prostatic cryosurgery. These results provide substantial motivation to further investigate VA as a potential modality to monitor prostate cryotherapy intraoperatively.
منابع مشابه
Vibroacoustography for the assessment of total hip arthroplasty
OBJECTIVES This paper proposes imaging with 3-dimensional vibroacoustography for postoperatively assessing the uncovered cup area after total hip arthroplasty as a quantitative criterion to evaluate implant fixation. METHODS A phantom with a bone-like structure covered by a tissue-mimicking material was used to simulate a total hip arthroplasty case. Vibroacoustography images of the uncovered...
متن کاملFeasibility of setting up a health promotion and disease prevention center with a healthy aging approach
Introduction: In spite of the global trend towards increased screening efforts, there remain instances where uncertainty surrounds the cost-effectiveness of this approach. In such cases, a comprehensive assessment that considers cost-effectiveness, feasibility, and factors related to epidemiology, socio-culture, and community becomes indispensable. This assessment offers crucial insights to gui...
متن کاملEstimation of spinal loads using a detailed finite element model of the L4-L5 lumbar segment derived by medical imaging kinematics; a feasibility study
Introduction: Low back pain is the most prevalent orthopedic disorder and the first main cause of poor working functionality in developed as wells as many developing countries. In Absence of noninvasive in vivo measurement approaches, biomechanical models are used to estimate mechanical loads on human joints during physical activities. To estimate joint loads via musculoskelet...
متن کاملCrawling wave detection of prostate cancer: preliminary in vitro results.
PURPOSE The focus of this article is to develop signal and imaging processing methods to derive an accurate estimation of local tissue elasticity using the crawling wave (CrW) sonoelastography method. The task is to reduce noise and to improve the contrast of the elasticity map. METHODS The protocol of the CrW approach was first tested on heterogeneous elastic phantoms as a model of prostate ...
متن کاملColorimetric Comparison of Tooth Color Change Following the Use of Two Endodontic Sealers: An Ex-Vivo Study
Background and Aim: Tooth discoloration induced by endodontic sealers is an un-desired outcome of endodontic treatment that affects the esthetic appearance of the teeth, which is important especially in the anterior region. The aim of the present study was to compare the coronal discoloration caused by two frequently used resin-based sealers namely EasySeal and AdSeal. Materials and Methods: F...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- IEEE transactions on bio-medical engineering
دوره 55 11 شماره
صفحات -
تاریخ انتشار 2008