Correction of scan time dependence of standard uptake values in oncological PET

نویسندگان

  • Jörg van den Hoff
  • Alexandr Lougovski
  • Georg Schramm
  • Jens Maus
  • Liane Oehme
  • Jan Petr
  • Bettina Beuthien-Baumann
  • Jörg Kotzerke
  • Frank Hofheinz
چکیده

BACKGROUND Standard uptake values (SUV) as well as tumor-to-blood standard uptake ratios (SUR) measured with [ 18F-]fluorodeoxyglucose (FDG) PET are time dependent. This poses a serious problem for reliable quantification since variability of scan start time relative to the time of injection is a persistent issue in clinical oncological Positron emission tomography (PET). In this work, we present a method for scan time correction of, both, SUR and SUV. METHODS Assuming irreversible FDG kinetics, SUR is linearly correlated to Km (the metabolic rate of FDG), where the slope only depends on the shape of the arterial input function (AIF) and on scan time. Considering the approximately invariant shape of the AIF, this slope (the 'Patlak time') is an investigation independent function of scan time. This fact can be used to map SUR and SUV values from different investigations to a common time point for quantitative comparison. Additionally, it turns out that modelling the invariant AIF shape by an inverse power law is possible which further simplifies the correction procedure. The procedure was evaluated in 15 fully dynamic investigations of liver metastases from colorectal cancer and 10 dual time point (DTP) measurements. From each dynamic study, three 'static scans' at T=20,35,and 55 min post injection (p.i.) were created, where the last scan defined the reference time point to which the uptake values measured in the other two were corrected. The corrected uptake values were then compared to those actually measured at the reference time. For the DTP studies, the first scan (acquired at (78.1 ± 15.9) min p.i.) served as the reference, and the uptake values from the second scan (acquired (39.2 ± 9.9) min later) were corrected accordingly and compared to the reference. RESULTS For the dynamic data, the observed difference between uncorrected values and values at reference time was (-52±4.5)% at T=20 min and (-31±3.7)% at T=35 min for SUR and (-30±6.6)% at T=20 min and (-16±4)% at T=35 min for SUV. After correction, the difference was reduced to (-2.9±6.6)% at T=20 min and (-2.7±5)% at T=35 min for SUR and (1.9% ± 6.2)% at T=20 min and (1.7 ± 3.3)% at T=35 min for SUV. For the DTP studies, the observed differences of SUR and SUV between late and early scans were (48 ± 11)% and (24 ± 8.4)%, respectively. After correction, these differences were reduced to (2.6 ± 6.9)% and (-2.4±7.3)%, respectively. CONCLUSION If FDG kinetics is irreversible in the targeted tissue, correction of SUV and SUR for scan time variability is possible with good accuracy. The correction distinctly improves comparability of lesion uptake values measured at different times post injection.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Physiological distribution and range of normal SUVmax values of 18F-Choline PET/CT

Introduction: 18F-Choline PET-CT is an increasingly used technique in patients with prostate cancer. The main indication is to localise the disease in patients with biochemical recurrence. To accurately interpret 18F-Choline PET, knowledge of normal tracer distribution is paramount. The aim of this study was to describe the normal distribution pattern of 18F-Cho...

متن کامل

Effects of MR based attenuation correction on clinical interpretation and quantification of [18F]flutemetamol scans: A comparison between PET/CT and PET/MR

Purpose [ 18 F]Flutemetamol (FMM) binds to amyloid-β, which is enhanced in Alzheimer's disease (AD). Recently, PET/MR systems have become available enabling acquisition of MR and human amyloid images in a single scanning session. PET/MR systems use MR based attenuation correction (MR-AC), which does not include actual attenuation coefficients, but rather uses tissue segmentation with allocation...

متن کامل

Effect of scatter coincidences, partial volume, positron range and non-colinearity on the quantification of FDOPA Patlak analysis

Introduction: The key characteristics of positron emission tomography (PET) are its quantitative capability and its sensitivity, which allow the in vivo imaging of biochemical interactions with small amounts of tracer concentrations. Therefore, accurate quantification is important. However, it can be sensitive to several physical factors. The aim of this investigation is the assessment of the e...

متن کامل

A Partial Volume Effect Correction Tailored for 18F-FDG-PET Oncological Studies

We have developed, optimized, and validated a method for partial volume effect (PVE) correction of oncological lesions in positron emission tomography (PET) clinical studies, based on recovery coefficients (RC) and on PET measurements of lesion-to-background ratio (L/B m) and of lesion metabolic volume. An operator-independent technique, based on an optimised threshold of the maximum lesion upt...

متن کامل

Sports activity done five days before PET/CT results in augmented FDG uptake in skeletal muscles

Increased metabolic activity in muscle secondary to excessive muscle activity during the uptake phase and shortly before FDG injection is a known phenomenon. We present FDG PET/CT findings in a young male, known case of carcinoma maxilla His scan showed diffuse increased metabolic activity in multiple skeletal muscle groups. There was history of unaccustomed, strenuous sports activity of skiing...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 4  شماره 

صفحات  -

تاریخ انتشار 2014