Explicit Relations between Electrical Transient Characteristics and Structure-parameters of Superconducting Generators under Sudden Short-circuit Faults
نویسندگان
چکیده
Superconducting generators (SCGs) have many advantages as compared with conventional ones, and practical use is expected. Before practical use, it is necessary and important to have a good grasp of the electrical characteristics of SCG under short-circuit conditions. And it is desirable that, relations between characteristics and structureparameters of generators are explicitly and simply expressed. We obtained transient characteristics of armature current and field current for SCG by use of mathematical electro-magnetic field analyses, and studied relations between characteristics and structure-parameters of machines. In this paper, the method of solution is explained for the sudden line-to-neutral short-circuits, while only the results are quoted for the line-to-line, and the doubleline-to-neutral short-circuits. Comparisons between analytical and experimental, using 20kVA SCG, results were also studied. Consequently, the parameters that dominate the amplitude of transient current were clarified. Besides that, close agreements between analytical and experimental results were obtained.
منابع مشابه
Artificial Intelligence Based Approach for Identification of Current Transformer Saturation from Faults in Power Transformers
Protection systems have vital role in network reliability in short circuit mode and proper operating for relays. Current transformer often in transient and saturation under short circuit mode causes mal-operation of relays which will have undesirable effects. Therefore, proper and quick identification of Current transformer saturation is so important. In this paper, an Artificial Neural Network...
متن کاملInfluence of Fault Current Limiter in Voltage Drop and TRV Considering Wind Farm
Influence of distributed generation systems in the distribution systems can increase the level of short-circuit current. The effectiveness of distributed generation systems is affected by the size, location, type of distributed generation systems technology, and the methods of connecting to distribution systems. Wind turbine system is the examples of distributed generation source. Not only does...
متن کاملA Comprehensive Mathematical Model for Analysis of WR-Resolvers under Stator Short Circuit Fault
Wound-Rotor (WR) resolvers are the most widely used position sensors in applications with harsh environmental conditions. However, their performance is exposed to failure due to the high risk of short circuit (SC) fault. Although the output current of the resolver is negligible, its thin copper wires increase the probability of the short circuit fault. To avoid the propagation of the turn-to-tu...
متن کاملPerformance Analysis of Disk Type Variable Reluctance Resolver under Mechanical and Electrical Faults
Disk Type Variable Reluctance (DTVR) resolvers have distinguished performance under run out fault comparing to conventional sinusoidal rotor resolvers. However, their accuracy under inclined rotor fault along with different types of eccentricities includes static and dynamic eccentricities are questioned. Furthermore, due to thin copper wires that are used for signal and excitation coils of res...
متن کاملDecreasing Distribution Generation Effects on Grid Short Circuit Level Using Superconducting Fault Current Limiter Through Updating Relays Set-Points
Power system protection at transmission and distribution levels based on overcurrent relays is essential based on their properties such as detection, stability, high speed, backup and error correction accuracy. Since distributed generation sources are connected to the power grid, they not only increase the short circuit level of the grid, but also disrupt the set point of main and backup relays...
متن کامل