Acetabular components with or without screws in total hip arthroplasty

نویسندگان

  • Murad Pepe
  • Onur Kocadal
  • Tamer Erener
  • Kubilay Ceritoglu
  • Ertugrul Aksahin
  • Cem Nuri Aktekin
چکیده

AIM To compare the operation time, blood loss, and early outcomes of acetabular components with and without the screw. METHODS Thirty patients who underwent cementless acetabular component with or without screw and whose follow-up exceeded one year period in total hip arthroplasty were evaluated. A posterior approach was used in all surgical procedures by one experienced surgeon. Demographic data, operation time, intra- and postoperative blood loss volume, follow-up clinical score, cup migration, and osteolysis were recorded. The Kolmogorov-Smirnov test was performed for testing the normality of study data. Mann-Whitney U test was used to analyze the inter-group differences. A P-value of ≤ 0.05 was considered statistically significant. RESULTS Acetabular components were used in 16 (53.3%) patients with screw and 14 (46.7%) without screw. After one year of follow-up, an osteolytic lesion of 3 mm was found in only one patient in the screw group. No cup migration was encountered. Intra-group mean Harris hip score significantly increased, but there was no significant inter-group difference. While the mean operation time of the screw group was 121.8 min (range; 95-140), it was 102.7 min (range; 80-120) in the no-screw group, and this difference was statistically significant (P = 0.002). The mean intraoperative/postoperative, and total blood loss were 556.6 mL (range: 350-800)/423.3 mL (range: 250-600), and 983.3 mL (range: 600-1350), respectively in the screw group; and 527 mL (range: 400-700)/456 mL (range: 230-600), and 983 mL (range: 630-1250), respectively in the no-screw group. The blood loss difference between the two groups was not significant. In the screw group, the operation time was 19.1 min longer than the no-screw group, and this difference was statistically significant. CONCLUSION Acetabular components with or without screw have similar results, but the use of screw increases the operation time significantly, while not changing the blood loss volume.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cementless Hip Arthroplasty in Southern Iran, Midterm Outcome and Comparison of Two Designs

Background: Cementless hip prosthesis was designed to provide biologic fixation, without the use of cement. The second generation components have shown more reliable bone ingrowths and survival rates. We are reporting a midterm result of two designs of cementless prosthesis in a unique culture with different social habits and expectations.Methods: 52 primary cementless total hip arthroplasty in...

متن کامل

Total hip replacement for developmental dysplasia of the hip.

Total hip arthroplasty relieves pain and improves function for many patients with endstage arthritis secondary to developmental dysplasia of the hip. Acetabular dysplasia, however, presents a special problem for total hip reconstruction in these patients. Structural bone grafting with femoral head autografting to the dysplastic acetabulum and cementing acetabular components into the graft provi...

متن کامل

Acetabular Reconstruction in Total Hip Arthroplasty

The difficulties encountered in dealing with the bone deficient acetabulum are amongst the greatest challenges in hip surgery. Acetabular reconstruction in revision total hip arthroplasty can successfully be achieved with hemispherical components featuring a porous or roughened ingrowth surface and options for placement of multiple screws for minor acetabular defect. Acetabular component select...

متن کامل

Migration pattern of cementless press fit cups in the presence of stabilizing screws in total hip arthroplasty

The aim of this study was to evaluate the initial acetabular implant stability and late acetabular implant migration in press fit cups combined with screw fixation of the acetabular component in order to answer the question whether screws are necessary for the fixation of the acetabular component in cementless primary total hip arthroplasty. One hundred and seven hips were available for follow-...

متن کامل

Reconstruction of the Acetabulum in Developmental Dysplasia of the Hip in Total Hip Replacement

Developmental dysplasia of the hip (DDH) or congenital hip dysplasia (CDH) is the most prevalent developmental childhood hip disorder. It includes a wide spectrum of hip abnormalities ranging from dysplasia to subluxation and complete dislocation of the hip joint. The natural history of neglected DDH in adults is highly variable. The mean age of onset of symptoms is 34.5 years for dysplastic DD...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2017