Evaluation of slice shear force as an objective method of assessing beef longissimus tenderness.
نویسندگان
چکیده
Experiments were conducted to develop an optimal protocol for measurement of slice shear force (SSF) and to evaluate SSF as an objective method of assessing beef longissimus tenderness. Whereas six cylindrical, 1.27-cm-diameter cores are typically removed from each steak for Warner-Bratzler shear force (WBSF) determination, a single 1-cm-thick, 5-cm-long slice is removed from the lateral end of each longissimus steak for SSF. For either technique, samples are removed parallel to the muscle fiber orientation and sheared across the fibers. Whereas WBSF uses a V-shaped blade, SSF uses a flat blade with the same thickness (1.016 mm) and degree of bevel (half-round) on the shearing edge. In Exp. 1, longissimus steaks were acquired from 60 beef carcasses to determine the effects of belt grill cooking rate (very rapid vs. rapid) and conditions of SSF measurement (hot vs cold) on the relationship of SSF with trained sensory panel (TSP) tenderness rating. Slice shear force was more strongly correlated with TSP tenderness rating when SSF measurement was conducted immediately after cooking (r = -.74 to -.76) than when steaks were chilled (24 h, 4 degrees C) before SSF measurement (r = -.57 to -.72). When SSF measurement was conducted immediately after cooking, the relationship of SSF with TSP tenderness rating did not differ among the belt grill cooking protocols used to cook the SSF steak. In Exp. 2, longissimus steaks were acquired from 479 beef carcasses to compare the ability of SSF and WBSF of 1.27-cm-diameter cores to predict TSP tenderness ratings. Slice shear force was more strongly correlated with sensory panel tenderness rating than was WBSF (r = -.82 vs -.77). In Exp. 3, longissimus steaks were acquired from 110 beef carcasses to evaluate the repeatability (.91) of SSF over a broad range of tenderness. Slice shear force is a more rapid, more accurate, and technically less difficult technique than WBSF. Use of the SSF technique could facilitate the collection of more accurate data and should allow the detection of treatment differences with reduced numbers of observations and reduced time requirements, thereby reducing research costs.
منابع مشابه
Tenderness classification of beef: II. Design and analysis of a system to measure beef longissimus shear force under commercial processing conditions.
The objectives of this study were to evaluate the efficacy of a system for classifying beef for tenderness based on a rapid, simple method of measuring cooked longissimus shear force. Longissimus steaks (2.54 cm thick) were trimmed free of s.c. fat and bone and rapidly cooked using a belt grill. A 1-cm-thick, 5-cm-long slice was removed from the cooked longissimus parallel with the muscle fiber...
متن کاملOn-line classification of US Select beef carcasses for longissimus tenderness using visible and near-infrared reflectance spectroscopy.
The current experiment was conducted to evaluate the on-line application of visible and near-infrared spectroscopy (VISNIR) to US Select carcasses during commercial beef carcass grading procedures to predict tenderness of longissimus steaks after 14 days of refrigerated storage. A regression model was calibrated using 146 carcasses and tested against an additional 146 carcasses. Carcasses were ...
متن کاملTenderness classification of beef: III. Effect of the interaction between end point temperature and tenderness on Warner-Bratzler shear force of beef longissimus.
The objectives of this experiment were to determine 1) whether end point temperature interacts with tenderness to affect Warner-Bratzler shear force of beef longissimus and 2) if so, what impact that interaction would have on tenderness classification. Warner-Bratzler shear force was determined on longissimus thoracis cooked to either 60, 70, or 80 degrees C after 3 and 14 d of aging from carca...
متن کاملThe efficacy of three objective systems for identifying beef cuts that can be guaranteed tender.
The objective of this study was to determine the accuracy of three objective systems (prototype BeefCam, colorimeter, and slice shear force) for identifying guaranteed tender beef. In Phase I, 308 carcasses (105 Top Choice, 101 Low Choice, and 102 Select) from two commercial plants were tested. In Phase II, 400 carcasses (200 rolled USDA Select and 200 rolled USDA Choice) from one commercial pl...
متن کاملBeef longissimus slice shear force measurement among steak locations and institutions.
The objectives of this study were 1) to determine which longissimus thoracis et lumborum steaks were appropriate for slice shear force measurement and 2) to determine the among and within institution variation in LM slice shear force values of 6 institutions after they received expert training on the procedure and a standard kit of equipment. In experiment 1, longissimus thoracis et lumborum mu...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of animal science
دوره 77 10 شماره
صفحات -
تاریخ انتشار 1999