Functional reading acuity and performance: Comparison of 2 accommodating intraocular lenses.

نویسندگان

  • David Brown
  • Paul Dougherty
  • James P Gills
  • John Hunkeler
  • Donald R Sanders
  • Monica L Sanders
چکیده

PURPOSE To compare functional reading acuity and speed with 2 models of accommodating intraocular lenses (IOLs). SETTING Four of 12 investigative sites in a U.S. Food and Drug Administration (FDA) clinical study. METHODS In this observational study, which was part of an ongoing FDA clinical trial, the MNRead functional reading test was used to compare the reading performance of patients with bilateral Tetraflex IOLs (Group 1) and a consecutive series of patients with bilateral Crystalens IOLs (Group 2) presenting at approximately 1 year postoperatively at 4 ophthalmic practices. The 2 groups were well matched for age, sex, mean postoperative time, and mean level of postoperative corrected distance visual acuity. All examinations were scored at a central reading center. RESULTS Group 1 comprised 96 patients and Group 2, 55 patients. Patients in Group 1 read better than those in Group 2 at print sizes of 20/63 (P = .004), 20/50 (P = .002), 20/40 (P = .001), 20/32 (P = .003), and 20/25 (P = .001). A statistically significantly higher proportion of patients in Group 1 than in Group 2 read 80 words per minute or more throughout the range of print sizes (P = .002). CONCLUSION Near reading ability was better with the Tetraflex accommodating IOL than with the Crystalens accommodating IOL at all print sizes between 20/25 and 20/63.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Comparison of Reading Performance in Patients Implanted with the Tecnis ZMA00 and AT LISA 802 Multifocal Intraocular Lenses

The choices of intraocular lenses (IOLs) available for implantation in cataract patients are multitudinous. Each option features significant benefits for visual performance and the comfort of the patients, but there are also some inherent limitations in each case. The traditional approach of monofocal IOL implantation is effective in providing adequate distance visual acuity, but is limited in ...

متن کامل

Compared optical performances of multifocal and monofocal intraocular lenses (contrast sensitivity and dynamic visual acuity)

The functional results (contrast sensitivity and dynamic visual acuity) of 19 multifocal (3M design) and 14 all polymethylmethacrylate biconvex monofocal intraocular lenses (IOLs), 6 mm in optical diameter were compared. Best corrected visual acuity was > or = 8/10 (Monoyer chart) Parinaud 2 in all cases. Major differences of functional performance in favour of monofocal IOLs were found outside...

متن کامل

Comparative visual performance with monofocal and multifocal intraocular lenses

BACKGROUND To compare near, intermediate, and distance vision, and quality of vision using appropriate subjective questionnaires, when monofocal or apodized diffractive multifocal intraocular lenses (IOLs) are binocularly implanted. METHODS Patients with different binocular IOLs implanted were recruited after surgery and had their visual acuity tested, and quality of vision evaluated, at a si...

متن کامل

Visual and Refractive Outcomes of Phacoemulsification with Implantation of Accommodating versus Standard Monofocal Intraocular Lenses.

PURPOSE To compare distant and near visual function after cataract surgery with implantation of Crystalens HD or Tek-Clear as accommodating intraocular lenses (IOLs), versus SA60AT as a standard IOL. METHODS The study included 62 eyes of 58 patients divided into three groups using three different IOLs: Crystalens HD (Bausch and Lomb, NY, USA), Tek-Clear (Tekia, CA, USA) and SA60AT (Alcon, TX,...

متن کامل

Prospective functional and clinical comparison of bilateral ReZoom and ReSTOR intraocular lenses in patients 70 years or younger.

PURPOSE To compare clinical outcomes, functional vision, and spectacle freedom in patients 70 years or younger with bilateral ReSTOR (Alcon Laboratories) or ReZoom (Advanced Medical Optics) intraocular lenses (IOLs). SETTING Private practice, Los Altos, California, USA. METHODS Thirty patients had nonrandomized bilateral implantation of a ReZoom or ReSTOR multifocal IOL. Patients were 70 ye...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of cataract and refractive surgery

دوره 35 10  شماره 

صفحات  -

تاریخ انتشار 2009