Treponemal antibody-absorbent enzyme immunoassay for syphilis.

نویسندگان

  • J Chen
  • T M Lin
  • C M Schubert
  • S P Halbert
چکیده

An enzyme immunoassay for the diagnosis of syphilis (ELISA-SY) was developed with solid-phase extracts of Treponema pallidum, specimen diluent containing Reiter treponeme absorbent, and three 30-min incubations. The ELISA-SY results were determined in comparison with a standardized positive control and reported as a percentage of strong positive control. In tests with 1,005 serum samples from a venereal disease clinic and other sources, 98.2% agreement was found with fluorescent treponemal antibody-absorption (FTA-ABS) results, and 98.3% agreement was found with T. pallidum passive hemagglutination (PHA) findings. Only 1 of 29 sera originally considered to be biologically false-positive by ELISA-SY; the latter specimen was also positive by PHA and FTA-ABS tests performed in our laboratories. Serum samples from clinically diagnosed syphilitics (16 primary-stage isolates, 7 secondary-stage isolates, and 3-latent-stage isolates) were all positive by ELISA-SY, FTA-ABS, and PHA. Serum samples from 51 newborns suspected of having syphilis on the basis of positive cardiolipin flocculation tests showed 98% agreement of ELISA-SY results with FTA-ABS and PHA findings. Sera from all 61 patients with a variety of autoimmune and other diseases known to be associated with biologically false-positive reactions for syphilis were negative by this ELISA-SY. The specificity of the ELISA procedure for T. pallidum antibody was also confirmed immunologically by blocking experiments.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of a Treponema pallidum enzyme immunoassay as a screening test for syphilis.

The CAPTIA Syphilis-G enzyme immunoassay for the detection of antibodies to Treponema pallidum was evaluated as a screening test for syphilis in comparison with the standard rapid plasma reagin (RPR) test. One thousand samples were tested, and the standard fluorescent treponemal antibody absorption test and the standard microhemmaglutination test were used to confirm the presence of treponemal ...

متن کامل

Evaluation of a new competitive immunoassay (BioElisa Syphilis) for screening for Treponema pallidum antibodies at various stages of syphilis.

The BioElisa Syphilis, a new competitive enzyme immunoassay (EIA) for Treponema pallidum whole antigen that uses specific human immunoglobulin G (IgG) antibodies as the competitor, was evaluated for potential use in screening for syphilis at various stages. The results obtained by this competitive EIA were compared with those obtained by the fluorescent treponemal antibody absorption (FTA-abs) ...

متن کامل

Evaluation of the Bio-Rad BioPlex 2200 syphilis multiplex flow immunoassay for the detection of IgM- and IgG-class antitreponemal antibodies.

The laboratory diagnosis of syphilis is based primarily upon serologic findings. Historically, serologic testing for syphilis has relied on assays such as rapid plasma reagin, fluorescent treponemal antibody absorption, Treponema pallidum particle agglutination (TP-PA), and more recently, enzyme immunoassay (EIA). In this study, we evaluated the performance of a novel multiplex flow immunoassay...

متن کامل

Cost effectiveness of enzyme immunoassay and immunoblot testing for the diagnosis of syphilis.

The burden of disease and associated health-care costs of syphilis are significant despite widespread screening and treatment. Our objective was to conduct an economic evaluation using a simulation model when comparing enzyme immunoassay (EIA) initial testing and Inno-Lia (IL) confirmatory testing (EIA + IL) with rapid plasma reagin (RPR) initial testing and Treponema pallidum particle agglutin...

متن کامل

Evaluation of an enzyme immunoassay for IgM antibodies to Treponema pallidum in syphilis in man.

An enzyme immunoassay (EIA) for the detection of immunoglobulin M (IgM) antibodies to Treponema pallidum was investigated for specificity and sensitivity. Using the results in serum from 1192 patients with successfully treated syphilis, the assay was calculated to be about 97% specific. As in any other IgM enzyme linked immunosorbent assay (ELISA), rheumatoid factor played an important part in ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 23 5  شماره 

صفحات  -

تاریخ انتشار 1986