Grayscale inversion radiographic view provided improved intra- and inter-observer reliabilities in measuring spinopelvic parameters in asymptomatic adult population

نویسندگان

  • Weixiang Sun
  • Jin Zhou
  • Xiaodong Qin
  • Leilei Xu
  • Xinxin Yuan
  • Yang Li
  • Yong Qiu
  • Zezhang Zhu
چکیده

BACKGROUND Recently, a grayscale inversion view was reported to improve intra- and inter-observer reliabilities in measuring coronal curvature with Cobb and pedicle methods in scoliosis patients. However, the grayscale transformation has never been applied to the measurements of spinopelvic parameters. The purpose of this study was to compare the measurement reliabilities of the spinoplevic sagittal parameters between the 'Standard View' and the 'Grayscale Inversion View' in normal adult populations. METHODS A total of 30 asymptomatic subjects aged between 30 and 40 years were included in this study. Whole-spine posteroanterior radiographs were used to measure the spinoplevic sagittal parameters including thoracic kyphosis (TK), lumbar lordosis (LL), sagittal vertical axis (SVA), pelvic incidence (PI), sacral slope (SS) and pelvic tilt (PT) in both standard view and grayscale inversion view. Two independent observers measured the parameters twice at a 2-week interval. Intra- and inter-observer reliabilities were compared between the two radiographic views. The absolute differences between the two sets of measurements on each view were calculated and compared. RESULTS The intra-class correlation coefficients (ICCs) of PI, PT and SVA were greater in the grayscale inversion view than in the standard view (0.972 vs 0.817, 0.937 vs 0.833 and 0.964 vs 0.901 for observer 1, respectively; 0.990 vs 0.826, 0.995 vs 0.842 and 0.969 vs 0.919 for observer 2, respectively). Overall, the improvement of ICC was greater in parameters of sagittal pelvic alignment than in those of sagittal spinal alignment. As for the mean absolute differences between two measurements, significant differences existed between the two views in terms of PI, PT and SVA (p = 0.014, 0.016 and 0.011 for observer 1, respectively; p = 0.014, 0.025 and 0.046 for observer 2, respectively). CONCLUSIONS A grayscale inversion view provided improved intra- and inter-observer reliabilities in measuring spinoplevic alignment when compared with a standard view. This view was more useful in subjects whose pelvic anatomical structures can't be identified clearly on the standard X-ray view.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A comparison of the validity and reliability between a digital radiographic imaging system and manual method in measuring the Cobb angle

Methods Twenty adolescents with scoliotic curvatures were chosen to participate in the study based on convenience, without predilection for gender, age, type or location. Images of the curvatures were examined by 15 trained observers to estimate the Cobb angle variability, as well as intraand inter-observer variations. Each image was measured three times at a minimum interval of one week betwee...

متن کامل

Comparison of Double and Single Leg Weight-Bearing Radiography in Determining Knee Alignment

  Background: Knee malalignment is an important modifiable cause of osteoarthritis (OA). Surgical therapeutic procedures depend on proper knee alignment assessment. The purpose of this study was to compare knee alignment parameters between double and single leg weight-bearing radiographs and to evaluate the reproducibility of inter- and intra-observer measurements. Methods: One hundred eight p...

متن کامل

The Role of Spinopelvic Parameters in Clinical Outcomes of Spinal Osteotomies in Patients with Sagittal Imbalance

Background: Sagittal imbalance is known as the main radiographic driver of disability in adult spinal deformity (ASD).In this study, the association of radiological spinopelvic parameters and clinical outcomes was evaluated following thecorrective surgery of sagittal imbalance, in order to explore the predictive ability of each parameter.Methods: A total of 23 patients, who underwent corrective...

متن کامل

Computer-Assisted Radiographic Calculation of Spinal Curvature in Brachycephalic “Screw-Tailed” Dog Breeds with Congenital Thoracic Vertebral Malformations: Reliability and Clinical Evaluation

The objectives of this study were: To investigate computer-assisted digital radiographic measurement of Cobb angles in dogs with congenital thoracic vertebral malformations, to determine its intra- and inter-observer reliability and its association with the presence of neurological deficits. Medical records were reviewed (2009-2013) to identify brachycephalic screw-tailed dog breeds with radiog...

متن کامل

بررسی مقایسه‌ای دقت Cone beam CT، رادیوگرافی داخل دهانی و پروب پریودنتال در اندازه‌گیری ضایعات استخوانی پریودنتال

Background and Aims: Cone beam computed tomography (CBCT) produces high-quality data about diagnosis and periodontal treatment. To date, there is not enough research regarding periodontal bone measurement using CBCT. The aim of this study was to compare the accuracy of CBCT in measuring periodontal defects to that of intraoral radiography and probing methods.Materials and Methods: Two-hundred a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 17  شماره 

صفحات  -

تاریخ انتشار 2016