LV Dyssynchrony Assessed With Phase Analysis on Gated Myocardial Perfusion SPECT Can Predict Response to CRT in Patients With End-Stage Heart Failure

نویسندگان

  • Nasrin Azizian
  • Fereydoon Rastgou
  • Tahereh Ghaedian
  • Allahyar Golabchi
  • Behdad Bahadorian
  • Vida Khanlarzadeh
  • Zahra Azizian
  • Majid Haghjoo
چکیده

BACKGROUND Cardiac resynchronization therapy (CRT) is an established treatment in patients with end-stage heart failure and wide QRS complex. However, about 30% of patients do not benefit from CRT (non-responder). Recent studies with tissue Doppler imaging yielded disappointing results in predicting CRT responders. Phase analysis was developed to allow assessment of LV dyssynchrony by gated single photon emission computed tomography (SPECT) myocardial perfusion imaging (GMPS). OBJECTIVES The aim of present study was to investigate the role of quantitative GMPS-derived LV dyssynchrony data to predict CRT responder. PATIENTS AND METHODS Thirty eligible patients for CRT implantation underwent GMPS and echocardiography. Response to CRT was evaluated six months after the device implantation. Clinical response to CRT was defined as 50 meters increase in 6-minute walking test (6-MWT) distance. Echocardiographic response to CRT was defined as ≥ 15% decrease in left ventricular end-systolic volume (LVESV). The lead position was considered concordant if it was positioned at the area of latest mechanical activation, and discordant if located outside the area of latest mechanical activation. RESULTS Clinical response to CRT was observed in 74% of patients. However, only 57% of patients were responder according to the echo criteria. There were statistically significant differences between CRT responders and non-responders for GMPS-derived variables, including phased histogram bandwidth (PHB), phase SD (PSD), and Entropy. Moreover, a cutoff value of 112° for PHB with a sensitivity of 72% and specificity of 70%, a cutoff value of 21° for PSD with a sensitivity of 90% and specificity of 74%, and a cutoff of 52% for Entropy with a sensitivity of 90% and a specificity of 80% were considered to discriminate responders and non-responders. CRT response was more likely in patients with concordant LV lead position compared to those with discordant LV lead position. CONCLUSIONS GMPS-derived LV dyssynchrony variables can predict response to CRT with good sensitivity and specificity.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Can LV dyssynchrony as assessed with phase analysis on gated myocardial perfusion SPECT predict response to CRT?

UNLABELLED Cardiac resynchronization therapy (CRT) is now a well-recognized therapeutic option for patients with end-stage heart failure. However, not all patients respond to CRT, and, therefore, preimplantation identification of responders is desirable. The aim of the present study was to investigate whether the degree of left ventricular (LV) dyssynchrony, as assessed with phase analysis from...

متن کامل

Evaluation of the potential impact of reconstruction method on dyssynchrony parameters derived by phase analysis of gated-SPECT MPI: Comparison of two quantitative software

Introduction: Gated SPECT myocardial perfusion scanning has new capabilities in addition to its main applications such as left ventricular dyssynchrony using phase analysis. Phase analysis has been investigated through various software including Emory Cardiac Toolbox (ECTb) and Quantitative Gated SPECT (QGS). The aim of this study is to evaluate the effect of reconstruction par...

متن کامل

Phase analysis of gated myocardial perfusion single-photon emission computed tomography compared with tissue Doppler imaging for the assessment of left ventricular dyssynchrony.

OBJECTIVES The purpose of this study was to compare left ventricular (LV) dyssynchrony assessment by gated myocardial perfusion single-photon emission computed tomography (SPECT) (GMPS) and tissue Doppler imaging (TDI). BACKGROUND Recently, it has been suggested that LV dyssynchrony is an important predictor of response to cardiac resynchronization therapy (CRT); dyssynchrony is predominantly...

متن کامل

Determination of normal ranges of regional and global phase parameters using gated myocardial perfusion imaging with Cedars-Sinai’s QGS software

Introduction: Myocardial perfusion imaging using gated SPECT and phase analysis is an effective tool in evaluation of mechanical dyssynchrony. The purpose of this study was to determine the normal ranges of global and regional phase parameters. Methods: A total of 100 patients with normal resting and stress electrocardiograms, low pretest likelihood for c...

متن کامل

The role of oral dipyridamole stress gated SPECT in assessing the response of the left ventricle to stress: Re-evaluation of an old method

Introduction: We aimed to assess whether the vasodilator effect of oral dipyridamole on the left ventricular systolic function in patients with suspected CAD is different from that of intravenous (IV) dipyridamole using Tc-99m MIBI myocardial perfusion gated SPECT. Methods: Eighty-nine patients (17 M / 72 W; 61 ± 10 years) were enrolled in this study. The patients underwent a dipyridamole stre...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 3  شماره 

صفحات  -

تاریخ انتشار 2014