Background: To evaluate gastrointestinal pathology in computed tomography (CT) scan, optimum distention, mural visualization and gastrointestinal tract discrimination are necessary. High attenuation oral contrast material in the form of iodine solution has drawbacks in mural visualization and tolerance. Milk can be used as a low attenuation CT oral contrast agent in gastrointestinal tract discrimination and mural visualization with better tolerance. Objective: The purpose of our study was to compare the effectiveness, cost, and tolerance of milk and iopamiro (iodinated positive contrast medium) in patients undergoing abdominal CT with oral and IV contrast media. Materials and Methods: Two hundred and twelve patients were purposively assigned to receive either whole milk (n = 110) or iopamiro (n = 100). Results were independently reviewed by radiologists. Degree of bowel distention, mural visualization and gastrointestinal tract discrimination were qualitatively scored on a 4point scale. A questionnaire regarding oral contrast tolerability was provided to each patient. Cost comparison of the two agents was performed. Results: No statistically significant differences were seen between whole milk and iopamiro with respect to degree of bowel distention and gastrointestinal tract discrimination for all segments of bowel studied (p > 0.05). Mural visualization is better with whole milk compared with iopamiro (p < 0.05). Significantly more patients ranked milk as pleasant in taste compared with iopamiro (p < 0.05). Milk was better tolerated than iopamiro, with fewer gastrointestinal side effects, including abdominal discomfort (p = 0.065), cramping (p = 0.309), nausea (p = 0.001), vomiting (p = 0.003) and diarrhea (p = 0.347). The cost per patient for iopamiro is 900 BDT compared with 60 BDT for milk. Conclusion: Whole milk is comparable to iopamiro with respect to bowel distention and gastrointestinal tract discrimination and better in bowel wall visualization and has better patient acceptance, and fewer adverse symptoms. Milk is a costeffective alternative to iopamiro as a low-attenuation CT oral contrast agent.
منابع مشابه
Validation of computed tomography-based attenuation correction of deviation between theoretical and actual values for four computed tomography scanners
Objective: In this study, we aimed to validate the accuracy of computed tomography-based attenuation correction (CTAC) using the bilinear scaling method.Methods: The measured attenuation coefficient (μm) was compared to a theoretical attenuation coefficient (μt ) using four different CT scanners and an RMI 467 phantom. The effective energy of the CT beam X-rays was calculated, using the aluminu...
متن کاملComputed tomography based attenuation correction in PET/CT: Principles, instrumentation, protocols, artifacts and future trends
The advent of dual-modality PET/CT imaging has revolutionized the practice of clinical oncology, cardiology and neurology by improving lesions localization and the possibility of accurate quantitative analysis. In addition, the use of CT images for CT-based attenuation correction (CTAC) allows to decrease the overall scanning time and to create a noise-free attenuat...
متن کاملClinical applications of virtual, non-contrast head images derived from dual-source, dual-energy cerebrovascular computed tomography angiography
Background: This study set out to evaluate the utility of cerebrovascular virtual non-contrast (VNC) scans. Materials and Methods: Conventional non-contrast (CNC) and dual-energy computed tomography angiography (DE-CTA) head scans were conducted on 100 subjects, of which 46 were normal, 15 had parenchymal hematomas of the brain, 13 had ischemic infarction, 22 had tumors, and 4 had calcified les...
متن کاملReversal Trend of Hounsfield Unit Values of Substances with High and Low Effective Atomic Numbers
Introduction: In dual-energy computed tomography (DECT), the Hounsfield values of a substance measured at two different energies are the basic data for finding the chemical properties of a substance. The trends of Hounsfield unit (HU) alterations following the changes in energy are different between the materials with high and low Zeff. The present study aim...
متن کاملEvaluation of effect of gold nanorods and spherical gold nanoparticles of different sizes on X-ray attenuation in computed tomography
Introduction: To date, gold nanoparticles (GNPs) have been demonstrated to have great potential as contrast agent for CT imaging and therapeutics. This study was designed to evaluate any effect on X-ray attenuation that might result from using GNPs with a variety of size, surface chemistries and shapes. Materials and Methods: Spherical GNPs and gold nanorod...