A pinhole gamma camera with optical depth-of-interaction elimination.
نویسندگان
چکیده
The performance of pinhole single photon emission computed tomography (SPECT) depends on the spatial resolution of the gamma-ray detectors used. Pinhole cameras suffer from strong resolution loss due to the varying depth-of-interaction (DOI) of gamma quanta that enter the detector material at an angle. We eliminate DOI effects in a scintillation gamma camera via a dedicated optic fiber bundle that acts as a focusing collimator for light generated in a scintillation crystal. A curved crystal is connected to a concavely shaped fiber-optic bundle such that the fibers connect perpendicularly to the crystal's convex surface and point straight at the pinhole opening. Limiting the fiber numerical apertures can be used to suppress resolution losses due to light spread. Here we demonstrate experimentally that this prototype position-sensitive gamma sensor successfully eliminates DOI effects, and has an intrinsic resolution of better than 280 microm full width at half maximum with an interaction probability of 67% for 140 keV photons. Therefore, the detector has great potential for increasing the resolution of pinhole SPECT.
منابع مشابه
A Thin Lens Based Camera Model for Depth Estimation from Defocus and Translation by Zooming
Depth recovery is a central concern in computer vision, and many methods were proposed for the monocular depth estimation by zooming as well as focusing and irising. In the past, there are two distinct approaches in depth by zooming; one is from motion parallax along the optical axis using a pinhole camera model, and the other from defocus using a thin lens camera model. This paper presents a n...
متن کاملGeneralising The Ideal Pinhole Model to Multi-Pupil Imaging For Depth Recovery
This thesis investigates the applicability of computer vision camera models in recovering depth information from images, and presents a novel camera model incorporating a modified pupil plane capable of performing this task accurately from a single image. Standard models, such as the ideal pinhole, suffer a loss of depth information when projecting from the world to an image plane. Recovery of ...
متن کاملCompact infrared pinhole fisheye for wide field applications.
The performances of a compact infrared optical system using advanced pinhole optics for wide field applications are given. This concept is adapted from the classical Tisse design in order to fit with infrared issues. Despite a low light gathering efficiency and a low resolution in comparison with classical lenses, pinhole imagery provides a long depth of field and a wide angular field of view. ...
متن کاملDerivation and validation of a sensitivity formula for knife-edge slit gamma camera: A theoretical and Monte Carlo simulation study
Introduction: Gamma cameras are proposed for online range verification and treatment monitoring in proton therapy. An Analytical formula was derived and validated for sensitivity of a slit collimator based on the photon fluence concept. Methods: Fluence formulation was generalized for photons distribution function and solved for high-energy point sources. The...
متن کاملA Geometrically Calibrated Pinhole Camera Model for Single Viewpoint Omnidirectional Imaging Systems
This paper presents a perspective imaging model that is able to display undistorted images captured with uncalibrated cameras on a cylindrical virtual screen and to detect the correct location of the viewing point respectively. By using a calibration pattern and thus avoiding complicated mathematical models, the optical center can be detected by tracking the optical rays generated by pairs of 3...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Physics in medicine and biology
دوره 54 13 شماره
صفحات -
تاریخ انتشار 2009