Treatment of syndesmotic disruptions of the ankle with bioabsorbable screw fixation.

نویسندگان

  • W David Hovis
  • Bryan W Kaiser
  • Jeffry T Watson
  • Robert W Bucholz
چکیده

BACKGROUND Bioabsorbable implants have restricted indications because of their unique biochemical properties and their inferior biomechanical properties compared with those of conventional metallic implants. The purpose of this prospective study was to assess the efficacy of screws made of polylevolactic acid (PLLA) in the treatment of syndesmotic disruptions associated with ankle fractures and fracture-dislocations. METHODS Thirty-three consecutive patients with a syndesmotic disruption were managed with standard metallic plate-and-screw fixation of the malleolar fracture and with 4.5-mm polylevolactic acid screws, with purchase in four cortices, for fixation of the syndesmosis. Intraoperative radiographs confirmed reduction of the syndesmosis, and all of the patients were managed with a non-weight-bearing plaster splint or brace for six weeks. Clinical and radiographic assessment and functional evaluation with use of the Olerud-Molander scoring system were performed at the time of follow-up. RESULTS Ten patients were lost to follow-up prior to the twenty-four-month evaluation, leaving twenty-three patients with an average duration of follow-up of thirty-four months (range, twenty-four to forty-three months). All of the malleolar fractures healed in an anatomical position at an average of three months, and no postoperative displacement of the syndesmosis or widening of the medial clear space was detectable on radiographs. No episodes of osteolysis or late inflammation secondary to the hydrolyzed polylactide occurred. Nineteen patients (83%) had an excellent result, and four patients (17%) had a good result. All twenty-three patients returned to their preinjury level of work and activities of daily living. No patient had malunion, nonunion, loss of reduction, or complications attributable to the biomechanical or biochemical properties of the implants. CONCLUSIONS Polylevolactic acid screws are effective in stabilizing disruption of the syndesmosis during healing of unstable ankle fractures. In this small series, the bioabsorbable screw was well tolerated, and there was no need for a second operation to remove it.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

CHAPTER 9 TECHNIQUE , OF SYI \ DESMOTIC REPAIR : Investigating the Innovative Tightrope ' * in Treatment of Syndesmotic Injuries

Fractures of the adult anlde with disruption of the tibiofibular syndesmosis call for sufficient stabilization of the ankle mortise to ensure proper healing of the syndesmotic ligaments. Several internal fixation techniques for stabilization of the syndesmosis have been employed in the past, including 3.5 mm, 4.5 mm, and 5.0 mm metallic and bioabsorbable screws, 1.5 mm and 1.5 mm Kirschner wire...

متن کامل

Long-term Results After Ankle Syndesmosis Injuries.

Syndesmotic disruption occurs in more than 10% of ankle fractures. Operative treatment with syndesmosis screw fixation has been successfully performed for decades and is considered the gold standard of treatment. Few studies have reported the long-term outcomes of syndesmosis injuries. This study investigated long-term patient-reported, radiographic, and functional outcomes of syndesmosis injur...

متن کامل

Overtightening of the syndesmosis revisited and the effect of syndesmotic malreduction on ankle dorsiflexion.

BACKGROUND Ankle syndesmotic injuries are a significant source of morbidity and require anatomic reduction to optimize outcomes. Although a previous study concluded that maximal dorsiflexion during syndesmotic fixation was not required, methodologic weaknesses existed and several studies have demonstrated improved ankle dorsiflexion after removal of syndesmotic screws. The purposes of the curre...

متن کامل

A prospective randomised study comparing TightRope and syndesmotic screw fixation for accuracy and maintenance of syndesmotic reduction assessed with bilateral computed tomography.

BACKGROUND The accuracy and maintenance of syndesmosis reduction are essential when treating ankle fractures with accompanying syndesmosis injuries. The primary aim of this study was to compare syndesmosis screw and TightRope fixation in terms of accuracy and maintenance of syndesmosis reduction using bilateral computed tomography (CT). STUDY DESIGN Single centre, prospective randomised contr...

متن کامل

Comparison of a novel Fiberwire-button construct versus metallic screw fixation in a syndesmotic injury model.

BACKGROUND There is minimal experience with less rigid syndesmotic fixation devices which may approximate the normal distal tibio-fibular mechanics during healing. This study evaluates the ability of a FiberWire-button implant (Arthrex, Naples, FL) to maintain syndesmotic reduction as compared with a metallic screw. METHODS Ten matched fresh-frozen cadaveric ankle pairs with intact ligaments ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Journal of bone and joint surgery. American volume

دوره 84-A 1  شماره 

صفحات  -

تاریخ انتشار 2002