چکیده
Objective: Electroencephalography (EEG) source reconstruction is becoming recognized as a useful technique to non-invasively localize the epileptic focus. Whereas, large array magnetoencephalography (MEG) systems are available since quite some time, application difficulties have previously prevented multichannel EEG recordings. Recently, however, EEG systems which allow for quick (10–20 min) application of, and recording from, up to 125 electrodes have become available. The purpose of the current investigation was to systematically compare the accuracy of epileptic source localization with high electrode density to that obtained with sparser electrode setups. Methods: Interictal epileptiform activity was recorded with 123 electrodes in 14 epileptic patients undergoing presurgical evaluation. Each single epileptiform potential was down sampled to 63 and 31 electrodes, and a distributed source model (EPIFOCUS) was used to reconstruct the sources with the 3 different electrode configurations. The localization accuracy with the 3 electrode setups was then assessed, by determining the distance from the inverse solution, maximum of each single spike to the epileptogenic lesion. Results: In 9/14 patients, the distance from the EEG source to the lesion was significantly smaller with 63 than with 31 electrodes, and increasing the number of electrodes to 123 increased this number of patients from 9 to 11. Simulations confirmed the relation between the number of electrodes and localization accuracy. Conclusions: The results illustrate the necessity of multichannel EEG recordings for high source location accuracy in epileptic patients. q 2002 Elsevier Science Ireland Ltd. All rights reserved.
منابع مشابه
Pii: S1388-2457(02)00297-3
For algorithm developers, this review details recent approaches to the problem, compares the accuracy of various algorithms, identifies common testing issues and proposes some solutions. For the algorithm user, e.g. electroencephalograph (EEG) technician or neurologist, this review provides an estimate of algorithm accuracy and comparison to that of human experts. Manuscripts dated from 1975 ar...
متن کاملPii: S1388-2457(02)00145-1
Objectives: This study explored whether the effects of repetitive transcranial magnetic stimulation (rTMS) on corticospinal excitability are dependent on the stimulation intensity and examined the effect of rTMS on inhibitory function. Methods: Nine normal volunteers received 15 min of 1 Hz rTMS at 85 and 115% of the resting motor threshold (RMT). Cortical excitability was measured before and a...
متن کاملPii: S1388-2457(02)00292-4
Objectives: The objective of this study is to test the hypothesis that the immature human brain exhibits slow electrical activity that is not detected by conventional (i.e. high-pass filtered) electroencephalography (EEG). Methods: Six healthy preterm infants (conceptional age 33–37 weeks) were recorded bedside with direct current (DC) EEG during sleep. Epochs with quiet sleep were selected to ...
متن کاملPii: S1388-2457(02)00262-6
Objective: Steady-state visual evoked potentials (VEPs) were recorded to study the mechanisms that underlie visual attention. Methods: VEPs were recorded from 1 cycle/degree sinusoidal grating contrast reversed at various temporal frequencies (6–10 Hz). This was displayed in one hemifield. A letter search display was flashed at a random rate in the other hemifield. The subject performed a deman...
متن کاملPii: S1388-2457(02)00303-6
Objective: To explore the reactivity of the theta and alpha rhythms during visuo-spatial working memory. Methods: One hundred and seventy-four subjects performed a delayed response task. They had to remember the spatial location of a target stimulus on a computer screen for a 1 or a 4 s retention interval. The target either remained visible throughout the entire interval (sensory trials) or dis...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -