Detection of Superior Vena Cava Obstruction on Dynamic 99mTc-DTPA Renal Transplant Scintigraphy
نویسندگان
چکیده
We present an asymptomatic patient with a history of prolonged hemodialysis through a right internal jugular vein catheter who was diagnosed with superior vena cava (SVC) obstruction on 99mTechnetium-diethylenetriaminepentaacetic acid renal transplant scintigraphy. During the angiographic phase, an unusual vascular filling pattern was detected on the anterior view of the abdomen. Angioscintigraphic imaging of the chest wall was suggestive of SVC obstruction. The SVC obstruction in our patient was related to the long-term use of an indwelling catheter in the central venous system, which is a well-known complication of such a procedure. There is also evidence of a hypercoagulable state in dialyzed uremic cases; therefore, our patient may have been more susceptible to an SVC thrombosis. Acquired compensatory dilatation of the azygos vein is rather a rare finding. To the best of our knowledge, this is the first report describing an asymptomatic patient with SVC obstruction who was diagnosed by renal scintigraphy.
منابع مشابه
Influence of bladder fullness on the detection of urinary tract obstruction by dynamic renal scintigraphy
OBJECTIVE To investigate the influence of bladder fullness on the diagnosis of urinary tract obstruction during dynamic renal scintigraphy with a diuretic stimulator. MATERIALS AND METHODS We studied 82 kidneys in 82 patients submitted to dynamic renal scintigraphy with a diuretic stimulator. We compared the proportional elimination of the radiopharmaceutical 99mTc-DTPA from the kidneys befor...
متن کامل"Hot spot" on hepatic scintigraphy [Persian]
Filling defects are often observed on 99mTc sulfur colloid liver scans. Hot spots are much less frequently seen. Superior vena cava syndrome is the most frequent cause of this finding. In this report 3 patients with S.V.C and budd - Chiari syndrome with HOT SPOT on liver scan are presented. Mechanisms of scintigraphic patterns are reviewed.
متن کاملComparison of relative renal function measured with either 99mTc-DTPA or 99mTc-EC dynamic scintigraphies with that measured with 99mTc-DMSA static scintigraphy.
OBJECTIVE The aim of this study was to compare the renal function measured with either 99mTc-DTPA or 99mTc-EC dynamic scintigraphies with that measured using 99mTc-DMSA static scintigraphy. METHODS the values of relative renal function measured in 111 renal dynamic scintigraphies performed either with 99mTc-DTPA (55 studies) or with 99mTc-EC (56 studies) were compared with the relative functi...
متن کاملPortosystemic shunting in superior vena cava obstruction by tumor demonstrated on ventilation-perfusion lung scan.
Extrapulmonary deposition of macroaggregated albumin particles on lung perfusion scintigraphy occurs in the presence of right-to-left shunting, as demonstrated in this case of portosystemic shunting related to superior vena cava obstruction by germ cell tumor of the mediastinum. The case demonstrates the importance of examining tracer deposition within the entire field of view on (99m)Tc-macroa...
متن کاملUnilateral renal agenesis revealed by hydronephrosis of contralateral kidney and explored by 99mTc-DMSA and 99mTc-DTPA scintigraphy
Renal scintigraphy is a physio-functional exploration permitting the exploration and assertion of unilateral renal agenesis. We report the case of a patient followed for a right hydronephrosis having revealed an agenesis of the contralateral kidney confirmed by 99mTc-DMSA scintigraphy. Also 99mTc-DTPA scintigraphy allowed the evaluation of the permeability of the urinary tract of the single rig...
متن کامل