Introduction: The laryngeal mask airway (LMA) is a common airway device used for anesthesia in ambulatory surgery, with a recently new described utilization in prone position. The aim of this study was to evaluate the safety and the effectiveness of the LMA, in prone position for anesthesia in ambulatory surgery, based on our new anesthesia department protocol. Methods: Patients from February 2013 to July 2014 were included in this prospective study. After the patient selfpositioning in prone position, general anesthesia was induced and the LMA was placed. Second generation LMA types were used (SupremeTM, iGelTM and ProsealTM) and all patients were mechanically ventilated. At the end of surgery, LMA was removed in prone or supine position. Number of attempts of LMA insertion, volume leak, airway peak pressure and complications were registered until 2 hours after the procedure. Results: The LMA placement was 85.1% effective in the first attempt and 100% in the second attempt. The need for a second attempt LMA placement was due to non-progression of the aspiration probe, a high leak and impossible ventilation. Mechanical ventilation was considered effective and safe with maximum peak airway pressure of 17.9 ± 5.5 cm H2O and maximum leak of 47.7 ± 31.2 ml. Complications were present in 6 patients (9%) with hypoventilation, bronchospasm and laryngospasm. Other “minor” events registered included the presence of blood in the LMA at the end of procedure and gum lesion with the rigid piece of the SupremeTM LMA. Discussion and conclusion: Complications found in our study are similar to those described in literature in supine position and are related to the anesthetist previous experience. Anesthetic depth adjustment improved all complications found. Effectiveness and overall safety of LMA use in prone position was observed, allowing further utilizations in selected patients according to the anesthesia department protocol.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Limitation of Laryngeal Mask Airway Usage in Open-Neck Procedure

I read the manuscript entitled “Case Report of An Open Neck Procedure Complication Associated with Laryngeal Mask Airway Use” by Subramaniam T et al. This is a valuable manuscript describing iatrogenic complications during level-2 cervical lymph node biopsy, in which the airway is managed with laryngeal mask airway (LMA). During the procedure, the surgeon realized that the mass was actually the...

متن کامل

Hemodynamic responses to insertion of the laryngeal mask airway versus Combitube

Introduction: One of the most common problems during laryngoscopy involves sympathetic system stimulation and the subsequent hemodynamic changes. It is a key measure to maintain the hemodynamic stability of patients with cardiovascular diseases during induction of anesthesia. This study attempted to compare the hemodynamic effects of laryngeal mask airway and combitube. Methods: This prospec...

متن کامل

مقایسه اثر استفاده از ماسک حنجره (Laryngeal mask airway) و لوله کافدار حلقی (Cuffed pharyngeal tube) در بروز گلودرد پس از بیهوشی عمومی در بزرگسالان

Post-operative sore throat is one of the most common complications and complaints of patients after general anesthesia especially in operations that need endotracheal intubations. Its causes are: size of endotracheal tube and type of its cuff, inadequate airway humidification, trauma during intubation and suctioning, high flow of inspiratory gases, surgical manipulation of airway and adjacent o...

متن کامل

Case Report of an open Neck Procedure Complication Associated with Laryngeal Mask Airway Use

Introduction: The laryngeal mask airway (LMA) is a safe method to establish airway control during general anaesthesia. In otolaryngology surgery, the use of a LMA is well established in ear surgery; however, the use of a LMA during open neck procedures remains controversial. We report a case in which the pharyngeal distortion by the LMA cuff resulted in an iatrogenic complication.   Case Report...

متن کامل

Airway management of a patient with tracheal stenosis for surgery in the prone position.

PURPOSE When tracheal intubation is required in a patient with an uncollapsible tracheal stenosis, the tip of the tube is usually positioned proximal to the stenosis. Only the tip of the tube may be in the trachea and the tube can be dislodged. We report the successful airway management of a patient with an uncollapsible tracheal stenosis who underwent cranial surgery in the prone position. C...