Percutaneous Retrieval and Redeployment of an Atrial Septal Occluder under Three-Dimensional Transesophageal Echocardiographic Guidance: A Case Report

نویسندگان

  • Jinhee Ahn
  • Jin Hee Kim
  • Jung Hyun Choi
  • Jun-Hyok Oh
چکیده

Percutaneous device closure for secundum atrial septal defects (ASDs) has been performed commonly and safely with high success rates. However, it is still challenging to close ASDs that are surrounded with deficient or hypermobile rims and could be compromised with an unexpected migration of device. We report a case of percutaneous Amplazter Septal Occluder (ASO; St. Jude Medical Inc., St. Paul, Minnesota, USA) device closure for an ASD with a thin and floppy interatrial septum, which immediately migrated into the right atrium and was not pulled back into the delivery sheath. To our knowledge, this is the first report on a successful percutaneous retrieval and redeployment of the device in such a situation, preventing any vascular injury or unplanned emergency open heart surgery.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Urgent Surgical Intervention for Embolized Cardiac Occluder Devices: A Case Series

Introduction: In this study, we sought to illustrate our experience in urgent surgical management for embolized cardiac septal occlude devices resulting from trans-catheter closure of atrial septal defect and ventricular septal defect. Mathrials and Methods: We retrospectively reviewed four patients aged 2–10 years who underwent urgent surgery due to cardiac septal occluder embolization between...

متن کامل

Cryptogenic stroke after percutaneous closure of an atrial septal defect.

We present the case of a patient who underwent a percutaneous secundum atrial septal defect (ASD II) closure with an undersized septal occluder device. One week and one month later she experienced two transient ischemic attacks. Three-dimensional transesophageal echocardiography (TEE) revealed a residual patent foramen ovale (PFO) with a positive Valsalva bubble test. She underwent a second pro...

متن کامل

Percutaneous retrieval of an interatrial septal occluder device embolized into the aortic arch.

Percutaneous closure of secundum atrial septal defects (ASD) may be complicated by immediate embolization. We report on a 35-year-old woman who underwent percutaneous device closure for a secundum ASD. The diameter of the defect was measured as 4 mm by two-dimensional transesophageal echocardiography and a 7-mm Figulla ASD occluder device was implanted without prior balloon sizing of the defect...

متن کامل

Transesophageal echocardiography-guided minimally invasive surgical device closure of an unusually shaped residual ventricular septal defect in a child.

Closure of residual ventricular septal defect with an occluder is traditionally performed by a percutaneous transcatheter approach under radiographic guidance. However, this procedure may be of limited use in cases with unusually shaped defects and in patients with low body weight. Here, we report minimally invasive surgical device closure of a 6 mm residual ventricular septal defect under tran...

متن کامل

Echocardiographic assessment and percutaneous closure of multiple atrial septal defects

Atrial septal defect closure is now routinely performed using a percutaneous approach under echocardiographic guidance. Centrally located, secundum defects are ideal for device closure but there is considerable morphological variation in size and location of the defects. A small proportion of atrial septal defects may have multiple fenestrations and these are often considered unsuitable for dev...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 29  شماره 

صفحات  -

تاریخ انتشار 2014