Evaluation of shaker dust collector for use in a swine farrowing barn

نویسندگان

  • Russell Sawvel
  • Russell Adam Sawvel
  • Matthew W. Nonnenmann
چکیده

Recommended Citation Sawvel, Russell. "Evaluation of shaker dust collector for use in a swine farrowing barn. ii To my beloved late Mother. iii ACKNOWLEDGMENTS I would like to thank my father Earl Sawvel and Sue Nordstrom for their support, guidance, and encouragement throughout this endeavor. I would also like to thank Tom Peters for being a world class advisor and Renée Anthony for being a worldly co-advisor. Their teamed leadership and demand for excellence kept my interest level strong. I am very thankful to the Occupational and Environmental Health department faculty and staff, my lab group, and fellow students. Outstanding individuals include: Jae Hong Park for his infinite wisdom; Ralph Altmaier for providing top notch laboratory support; Elanie Girlando and Deirdre Green for being wonderful classmates; Matt Nonnenmann for being a committee member; and Marty Jones for being a mentor. Thank you for making The University of Iowa a special place to be. iv ABSTRACT A shaker dust collector was evaluated to 1. determine filter capacity in terms of mass loading, pressure drop, airflow, and runtime; 2. determine particle collection efficiency by size prior to and following repeated loadings. A shaker dust collector was setup in the laboratory to take in contaminated air, collect dust, and exhaust treated air. For each loading test, Arizona road dust (~1 to 200 µm) was introduced into the airstream entering the dust collector at an emission rate and duration to simulate 3-months in a swine barn in winter. Filter pressure drop and exhaust velocity pressure were measured throughout loading. Filter collection efficiency was tested using polydisperse solid glass microspheres (~1 to 10 µm) and measured with an aerodynamic particle sizer at the startup and end of loadings. Cleaning cycles were run between loading tests. Overall efficiency was 44% for new filter, and ranged from 27% for 1-µm particles, increasing to 96% for 10-µm particles. Collection efficiency for loaded filter was 99% overall, and 99% over the range of 1 to 10-µm particles. Following cleaning, overall efficiency was 91%, and 91% for 1-µm particles, increasing to 99% for 10-µm particles. Exhaust airflow decreased linearly with pressure drop (R 2 =0.99) for all three loading tests. At startup, system airflows were approximately 1,700 m 3 hr-1 and at shutdown, system airflows were approximately 1,200 m 3 hr-1. Significant recovery of filter pressure drop was observed following primary cleanings (p<0.001). The shaker dust collector has adequate capacity …

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ammonia and Greenhouse Gas Emissions of a Swine Breeding-Gestation-Farrowing Facility in the Midwestern USA

Aerial emissions from livestock production continue to be an area of concern for both the potential health and environmental impacts. However, information on gaseous, especially greenhouse gas (GHG) emissions for swine breeding/gestation and farrowing production facilities is meager. A 4300-sow breeding, gestation, and farrowing facility in Iowa was selected for extensive field monitoring. A Mo...

متن کامل

Swine confinement buildings: effects of airborne particles and settled dust on airway smooth muscles.

Swine confinement workers are exposed to various contaminants. These agents can cause airway inflammation and bronchoconstriction. This study was undertaken to evaluate if the bronchoconstrictive effects of swine barn air and settled dust are mediated by endotoxin, and if these effects are directly mediated on airway smooth muscles. Mouse tracheas where isolated and mounted isometrically in org...

متن کامل

Exposure to hog barn dust alters airway epithelial ciliary beating.

Swine confinement workers are at increased risk of airway diseases, including mucus membrane irritation syndrome, chronic rhinosinusitis and chronic bronchitis. Dust extracts from swine confinement facilities stimulate the production of pro-inflammatory cytokines in bronchial epithelial cells, including interleukin (IL)-8. As IL-8 is capable of blocking beta-agonist-stimulated increases in cili...

متن کامل

Energy and carbon inventory of Iowa swine production facilities

0308-521X/$ see front matter 2010 Elsevier Ltd. A doi:10.1016/j.agsy.2010.06.003 * Corresponding author. Tel.: +1 515 294 4637; fax E-mail address: [email protected] (P.J. Lam This study evaluates energy and carbon use by two types of facilities—conventional confinement and hoop barn-based—within farrow-to-finish pig production systems scaled to produce 5200 and 15,600 market pigs annually i...

متن کامل

CXCR1/CXCR2 antagonist CXCL8(3-74)K11R/G31P blocks lung inflammation in swine barn dust-instilled mice.

Inhalation of agricultural occupational dusts from swine confinement facilities can result in lung inflammation. The innate immune response to organic barn dusts results in production of a number of pro-inflammatory factors in the lungs of barn workers such as cytokines, chemokines, and an influx of neutrophils. Many of these inflammatory factors are influenced by the chemokine CXCL8/IL-8 (KC o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016