A new technique for mounting and testing frame-supported homograft aortic valves.
نویسندگان
چکیده
The mounting of homograft aortic valves on rigid frames often produces cusp distortion leading to mechanical dysfunction. This dysfunction can be demonstrated by a simple testing apparatus. A technique of valve mounting has been developed which consistently results in a competent valve with exact and correct cusp apposition. It is clear that the effect of different techniques of sterilization and preservation on valve function cannot be adequately assessed unless valves are mechanically correct at the time of insertion.
منابع مشابه
Post-mortem shrinkage of homograft aortic valves.
Experience has shown that some frame-mounted homograft aortic valves, although competent immediately after mounting, are incompetent when subsequently presented for surgical use. Retraction and shrinkage of the cusps appears to be the cause of this change. Clinical and experimental studies have shown that shrinkage of homograft aortic valves occurs over an approximately five-day period after de...
متن کاملHomograft Crossmatching Is Unnecessary due to the Absence of Blood Group Antigens
Background. Homograft valves are subject to calcification and structural degeneration in the long term. Blood group matching is performed in many centers, and it remains controversial whether immunologic responses associated with potential blood group incompatibility contribute to the degeneration of unmatched homografts. We studied the expression of carbohydrate blood group antigens on valve e...
متن کاملThe fate of aortic valve homografts 12 to 17 years after implantation.
Results of long-term follow-up of an early cohort of patients receiving aortic valve homografts for aortic stenosis and aortic insufficiency are presented. All patients were operated upon by a single surgeon from 1966 to 1971. Eighty-three patients underwent insertion of 85 homograft aortic valves. Homografts were sterilized with either betapropiolactone (39 valves) or gamma irradiation (41 val...
متن کاملHomograft Aortic Valve Replacement in Aortic Incompetence and Stenosis.
The surgery of aortic incompetence and calcific aortic stenosis has made disappointing progress, chiefly because of the need for partial or total valve replacement in many of these patients and the technical problems inherent in designing an artificial valve. In rheumatic aortic incompetence it is now fairly clear that total replacement of the valve is almost always required (McGoon, Mankin, an...
متن کاملTransplantation of human homograft aortic valve.
We report the correction of aortic regurgitation by the insertion of a homograft aortic valve. The valve had been stored in buffered formaldehyde for six months, and this technique of preservation is the purpose of this communication. Formaldehyde in acetate buffer for the preservation of valve tissue was suggested to us by Lord Brock (1962), and this report of its use is believed to be the fir...