Comparison of Hybritech and WHO standardization
نویسنده
چکیده
Background. It is widely accepted that the introduction of the First International Standard for PSA assay (WHO96/670) improved the agreement between total PSA immunoassay. Less attention was given to the fact that the results obtained with WHO calibration turned out to be lower by 16-20% than the original Hybritech assay with the inevitable consequences on positive/negative false results. The aim of the study was to verify, on UniCel®DxI800, the misalignment between Hybritech and WHO calibration for total PSA assay and to calculate the new cut-off value if WHO calibrated. Methods. We measured total PSA values, in 500 samples, both with Hybritech and WHO calibration on UniCel®DxI800 (Beckman Coulter). Results. Our data confirm the negative bias of WHO values with respect to Hybritech values and on the grounds of Passing-Bablok regression, the 4.0 μg/L cut-off, obtained according to Hybritech total PSA assay, corresponds to a WHOcalibrated cut-off of 3.2 μg/L. Conclusions. When WHO calibration is used for a PSA assay, a new assay-dependant cut-off should be calculated or, if the laboratory decides to maintain the same cut-off value of PSA-Hyb with a WHO calibration, a redefinition of the sensibility/specificity of 4.0 μg/L cut-off is needed.
منابع مشابه
The Clinical Impact of Who Standardization of Psa Assays Klini^ki Uticaj Who Standardizacije Na Psa Testove
EAU Congress, Milan. 2008. 33. Stephan C, Kahrs A, Klotzek S, Reiche J, Müller C, LeinM, et al. Toward the metrological traceability in deter-mination of prostate-specific antigen: the new AccessHybritech assays calibrated against WHO standardscompared with the traditional Access Hybritech assays.CCLM 2008; in press. 34. Stephan C, Kahrs A, Klotzek S, Reiche J, Müller C, Lei...
متن کاملClinical impact of new prostate-specific antigen WHO standardization on biopsy rates and cancer detection.
BACKGROUND Clinicians may be unaware that replacement of the historical total prostate-specific antigen (tPSA) standard with the WHO 96/670 international standard leads to difficulties in interpreting tPSA results. Our aim was to investigate the relationship between the Hybritech and WHO calibrations of the Beckman Coulter tPSA assay, and to assess the impact on prostate cancer (PCa) detection....
متن کاملStandardization of Reasons for Living Inventory for Adolescents: Diagnosis, Appraisal, Therapy and Rehabilitation of People who Attempt
Objectives: In this study, assessed the reliability, validity, and predictive power of a new version of the Reasons for Living Inventory for Adolescents among Iranian Adolescents in the city of Kermanshah. Methods: To examine this study A group of 400(189 males and 211 females) adolescent in high schools of Kermanshah and adolescents that attempt to suicide and cared in Emam Khomeini hospita...
متن کاملSerum thyrotropin as measured with a one-step monoclonal-antibody radioimmunometric assay compared with two commercial radioimmunoassay kits.
We compared results obtained with a commercial immunoradiometric assay kit for human thyrotropin in which monoclonal antibodies are used (Tandem -R TSH (ONE STEP) ImmunoRadioMetricAssay; Hybritech Inc.) with those obtained with two commercial radioimmunoassay methods: GAMMA-DAB [125I]HS-hTSH RIA (Clinical Assays) and Thyro-SHure TSH Diagnostic Kit (Nuclear Medical Laboratories). The correlation...
متن کاملI-5: Semen Analysis - Clinical Laboratories; Is Standardization Applied?
Reduced semen quality is commonly claimed to be one of the main signs of male infertility and thus, analysis of semen is recommended as the cornerstone of a male fertility investigation. However, to control possible sources of physiological and methodological variation, and to generate reliable information on semen quality that can be accurately compared across different laboratories, semen ana...
متن کامل