Quantitation of fluoride ion released sarin in red blood cell samples by gas chromatography-chemical ionization mass spectrometry using isotope dilution and large-volume injection.

نویسندگان

  • E M Jakubowski
  • J M McGuire
  • R A Evans
  • J L Edwards
  • S W Hulet
  • B J Benton
  • J S Forster
  • D C Burnett
  • W T Muse
  • K Matson
  • C L Crouse
  • R J Mioduszewski
  • S A Thomson
چکیده

A new method for measuring fluoride ion released isopropyl methylphosphonofluoridate (sarin, GB) in the red blood cell fraction was developed that utilizes an autoinjector, a large-volume injector port (LVI), positive ion ammonia chemical ionization detection in the SIM mode, and a deuterated stable isotope internal standard. This method was applied to red blood cell (RBC) and plasma ethyl acetate extracts from spiked human and animal whole blood samples and from whole blood of minipigs, guinea pigs, and rats exposed by whole-body sarin inhalation. Evidence of nerve agent exposure was detected in plasma and red blood cells at low levels of exposure. The linear method range of quantitation was 10-1000 pg on-column with a detection limit of approximately 2-pg on-column. In the course of method development, several conditions were optimized for the LVI, including type of injector insert, injection volume, initial temperature, pressure, and flow rate. RBC fractions had advantages over the plasma with respect to assessing nerve agent exposure using the fluoride ion method especially in samples with low serum butyrylcholinesterase activity.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quantitation of diethylene glycol and its metabolites by gas chromatography mass spectrometry or ion chromatography mass spectrometry in rat and human biological samples.

The misuse of the commonly used chemical diethylene glycol (DEG) has lead to many poisonings worldwide. Methods were developed for analysis of DEG and its potential metabolites; ethylene glycol, glycolic acid, oxalic acid, diglycolic acid and hydroxyethoxy acetic acid in human urine, serum and cerebrospinal fluid samples, collected following a DEG-associated poisoning in the Republic of Panama ...

متن کامل

Determination of blood lead by electron-capture negative chemical ionization gas chromatography-mass spectrometry.

An electron-capture negative chemical ionization (NCI) gas chromatography-mass spectrometry (GC-MS) method for determination of lead (Pb) in blood samples is described. Extraction of Pb from the sample does not involve hot digestion but is based on treatment at ambient temperature. The blood sample is supplemented with a known amount of internal standard (204Pb) for isotope dilution and is trea...

متن کامل

Determination of nerve agent metabolites in human urine by isotope-dilution gas chromatography-tandem mass spectrometry after solid phase supported derivatization.

A simple and sensitive method has been developed and validated for determining ethyl methylphosphonic acid (EMPA), isopropyl methylphosphonic acid (IMPA), isobutyl methylphosphonic acid (iBuMPA), and pinacolyl methylphosphonic acid (PMPA) in human urine using gas chromatography-tandem mass spectrometry (GC-MS/MS) coupled with solid phase derivatization (SPD). These four alkyl methylphosphonic a...

متن کامل

Quantitation of choline and its metabolites in tissues and foods by liquid chromatography/electrospray ionization-isotope dilution mass spectrometry.

Choline is important for normal membrane function, acetylcholine synthesis, lipid transport, and methyl metabolism. The U.S. National Academy of Sciences recently set requirements for choline in the human diet. In tissues and foods, there are multiple choline compounds that contribute to choline content. Betaine, a derivative of choline, is also important because of its role in donation of meth...

متن کامل

Determination of ultra-trace levels of priority PBDEs in water samples by isotope dilution GC(ECNI)MS using 81Br-labelled standards.

A gas chromatography electron capture negative ionization mass spectrometry (GC(ECNI)MS) procedure for the determination of priority polybrominated diphenyl ethers (PBDEs; congeners 28, 47, 99, 100, 153 and 154) in water samples at regulatory EU levels has been developed. The method is based on the use of (81)Br-labelled PBDEs for isotope dilution analysis and the measurement of (79)Br/(81)Br i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of analytical toxicology

دوره 28 5  شماره 

صفحات  -

تاریخ انتشار 2004