Measurements of Corneal Thickness in Eyes with Pseudoexfoliation Syndrome: Comparative Study of Different Image Processing Protocols

نویسندگان

  • Katarzyna Krysik
  • Dariusz Dobrowolski
  • Katarzyna Polanowska
  • Anita Lyssek-Boron
  • Edward A Wylegala
چکیده

PURPOSE Comparative analysis of central and peripheral corneal thickness in PEX patients using three different imaging systems: Pentacam-Scheimpflug device, time-domain optical coherence tomography (OCT) Visante, and swept-source OCT Casia. MATERIALS AND METHODS 128 eyes of 80 patients with diagnosed PEX were examined and compared with 112 normal, non-PEX eyes of 72 cataract patients. The study parameters included 5 measured zones: central and 4 peripheral (superior, inferior, nasal, and temporal). RESULTS The mean CCT in eyes with PEX syndrome measured with all three instruments was thicker than that in normal eyes. Corneal thickness measurements in the PEX group were statistically significantly different between Pentacam and OCT Casia: central corneal thickness (p = 0.04), inferior corneal zone (p = 0.01), and nasal and temporal corneal zones (p < 0.01). Between Pentacam and OCT Visante inferior, nasal and temporal corneal zones were statistically significantly different (p < 0.01). Between OCT Casia and OCT Visante, there were no statistically significant differences in measured parameters values. CONCLUSION The central corneal thickness in eyes with PEX syndrome measured with three different independent methods is higher than that in the non-PEX group, and despite variable peripheral corneal thickness, this one parameter is still crucial in intraocular pressure measurements.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Central Corneal Thickness, Corneal Endothelial Cell Density, and Lens Capsule Thickness in Normotensive Patients with and without Pseudoexfoliation Syndrome

Purpose: To compare central corneal thickness (CCT), corneal endothelial cell density, and lens capsule thickness in normotensive patients with and without pseudoexfoliation syndrome (PXS) Methods: This was a prospective, comparative, descriptive study. Normotensive candidates for cataract surgery with (study group) and without (control group) PXS were enrolled in the study. CCT and corneal end...

متن کامل

Evaluation of the Endothelial Cell Density and the Central Corneal Thickness in Pseudoexfoliation Syndrome and Pseudoexfoliation Glaucoma

Purpose. Evaluation of central corneal thickness (CCT) and endothelial cell density (ECD) in patients with senile cataract and coexisting pseudoexfoliation (PEX) syndrome with glaucoma (PEXG) and without glaucoma using specular microscopy. Participants and Methods. The study included 122 patients (217 eyes). In this group of patients we identified 133 eyes with PEX syndrome (65 with glaucoma, 6...

متن کامل

[Morphometric changes of corneal endothelial cells in pseudoexfoliation syndrome and pseudoexfoliation glaucoma].

OBJECTIVE To evaluate the corneal endothelial morphometry and central corneal thickness (CCT) in pseudoexfoliative (PEX) eyes with and without glaucoma and to compare with normal eyes and eyes with primary open-angle glaucoma (POAG). METHOD A total of 166 patients were included in this study: 36 eyes with pseudoexfoliation syndrome (PXS), 30 eyes with pseudoexfoliation glaucoma (PXG), 40 eyes...

متن کامل

Comparison of Intraocular Pressure of Both Eyes in Patients with Unilateral Pseudoexfoliation Syndrome

Background & Aims: Pseudoexfoliation syndrome (PXS) is a complex disorder which causes an increase in intraocular pressure (IOP). This study was conducted in order to compare IOP of both eyes of patients with unilateral PXS. Methods: In a cross-sectional study from January 2011 to June 2012, 79 patients with unilateral PXS were studied. The patients were examined first with constricted, and the...

متن کامل

Central corneal thickness in subjects with glaucoma and in normal individuals (with or without pseudoexfoliation syndrome)

OBJECTIVE The evaluation of central corneal thickness (CCT) in subjects with pesudoexfoliation glaucoma (PEXG), primary open-angle glaucoma (POAG), and in normotensive individuals with or without pseudoexfoliation syndrome (PXS). STUDY DESIGN/PATIENTS AND METHODS CCT was evaluated with ultrasound pachymetry in a total of 179 individuals: 32 had bilateral PEXG, 55 had bilateral POAG, 35 had PX...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2017  شماره 

صفحات  -

تاریخ انتشار 2017