The Relationship between Portal Venous and Hepatic Arterial Blood Flow. I. Experimental Liver Transplantation
نویسندگان
چکیده
The relationship between the changes in portal venous and hepatic arterial blood flows, in the liver is a much disputed question, it has tremendous significance in the practice of transplantation, and an explanation has been available since 1981, when Lautt published the so-called "adenosine washout theory". According to our earlier observations the decrease of portal pressure or flow consistently led to an increase in hepatic artery flow. At the same time changes in hepatic artery flow or pressure seemed to produce only inconsistent effects on the portal circulation. In the present experiments liver transplantation (OLTX) was carried out on mongrel dogs by Starzl's method. Electromagnetic flow probes were placed on the hepatic artery and the portal vein before removal of recipient's liver, and after completion of all vascular anastomoses to the newly inserted liver, during the recirculatory phase of OLTX. The flow probes were connected to a Hellige electromagnetic flowmeter, portal venous and systemic arterial pressures were also recorded. The control HAF was 241 +/- 23 ml/min, the average PVF was 517 +/- 47 ml/min before removal of the recipient's liver. In the recirculatory phase of HAF increased, by 71 +/- 12% (p < 0.001). The PVF decreased in most animals after OLTX. The decrease was in average -40.2 +/- 3.5% (p < 0.001). The THBF calculated by adding the HAF and PVF showed a small, but not significant decrease recirculation. The systemic arterial pressure decreased slightly and portal vein pressure rose in most animals after OLTX. There was a substantial increase in portal inflow resistance and prehepatic arteriolar resistance and a decrease in hepatic artery resistance. The decrease of PVF after OLTX can be explained by progressive fluid accumulation in the liver parenchyma and increased sinusoidal and portal inflow resistance. The prolonged and continuous increase in hepatic artery flow during the recirculatory phase of OLTX may be due to the decrease of portal flow. The exact mechanism, by which a change in portal flow leads to arteriolar dilatation, can be most probably explained by the "adenosine washout theory" of Lautt.
منابع مشابه
Reconstruction of graft hepatic artery and portal vein with donor iliac vessel interposition in liver transplantation: one case report and review of the literature
A patient with friable hepatic artery and poor hepatic arterial inflow, portal vein thrombosis and serious gastroesophageal varices underwent modified piggyback liver transplantation. The hepatic artery was reconstructed by interposing donor’s iliac arterial conduit anastomosed to the infrarenal aorta, while the portal vein flow was ensured by the interposition of donor’s iliac venous graft. Th...
متن کاملHepatic arterial infusion with tumor necrosis factor-α induces early hepatic hyperperfusion.
BACKGROUND Hepatic arterial infusion (HAI) has been developed for high-dose regional chemotherapy of unresectable liver metastases or primary liver malignancies. While it is well known that high concentrations of tumor necrosis factor (TNF)-α damage tumor blood perfusion, there is no information on whether autochthonous liver perfusion is affected by HAI with TNF-α. Therefore, we investigated t...
متن کاملLocal control of hepatic arterial and portal venous flow in the dog.
HANSON, KENNETH M., AND PAUL C. JOHNSON. 4kzzl control of hepatic arterial and portal uenous jaw in the dog. Am. J. Physiol. 211(3): 712-720. I g66.-Hemodynamic studies were made in over IOO experiments on the denervated, autoperfused, dog liver in situ. Electromagnetic flowmeters were used. Data\ are given on pressure-flow relationships in both vascular circuits, with and without simultaneous ...
متن کاملصحت تشخیصی پارامترهای شریان کبدی و ورید پورت در داپلر سونوگرافی سیروز
Background: Cirrhosis and portal hypertension influence the hepatic circulation. The purpose of this study was to evaluate the diagnostic accuracy of liver Doppler ultrasonography parameters in cirrhosis.Methods: This case-control study involved 118 subjects. All case subjects had biopsy-proven hepatic cirrhosis. The controls were healthy people, case-matched for age and gender. All cases and c...
متن کاملShould Low Central Venous Pressure Be Maintained during Liver Transplantation?
Low central venous pressure, which indirectly reflects free hepatic venous pressure, is maintained during hepatic resection surgery to reduce intraoperative blood loss by facilitating hepatic venous outflow. However, whether the low central venous pressure protocol established for non-transplant hepatobiliary surgery should be generalized to liver transplantation is controversial because patien...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- HPB Surgery
دوره 10 شماره
صفحات -
تاریخ انتشار 1996