Validation of a novel point-of-care nerve conduction device for the detection of diabetic sensorimotor polyneuropathy.

نویسندگان

  • Bruce A Perkins
  • Jaspreet Grewal
  • Eduardo Ng
  • Mylan Ngo
  • Vera Bril
چکیده

OBJECTIVE The diagnosis of diabetic sensorimotor polyneuropathy using objective electrophysiological tests is hindered by limited access to the specialized laboratories and technicians that perform and interpret them. We evaluated the performance characteristics of a novel portable and automated point-of-care nerve conduction study device, which can be operated by nontechnical personnel, and compared it with conventional nerve conduction studies performed in a specialist setting. RESEARCH DESIGN AND METHODS Seventy-two consecutive patients with diabetes (8 type 1, 64 type 2) from a diabetes and a neuropathy outpatient clinic were evaluated concurrently with conventional nerve conduction studies (the reference standard) and the point-of-care device for sural nerve function (sural nerve amplitude potentials in microvolts [microV]). RESULTS Sural nerve amplitude potentials measured by the point-of-care device shared very strong correlation with the reference standard (Spearman's correlation coefficient 0.95, P < 0.001). The Bland and Altman method yielded agreement despite a small systematic underestimation by the point-of-care device of 1.2 +/- 3.4 microV. Despite this small systematic bias, the sensitivity and specificity of normal and abnormal sural nerve amplitude potentials measured by the point-of-care device for the detection of diabetic sensorimotor polyneuropathy defined by standard clinical and electrophysiological criteria were 92 and 82%, respectively. CONCLUSIONS A novel point-of-care device has excellent diagnostic accuracy for detecting electrophysiological abnormality in the sural nerve of patients who have diabetes. This automated device represents an alternative to conventional nerve conduction studies for the diagnosis of diabetic sensorimotor polyneuropathy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Multi-site testing with a point-of-care nerve conduction device can be used in an algorithm to diagnose diabetic sensorimotor polyneuropathy.

OBJECTIVE We aimed to establish whether multi-nerve testing with a point-of-care nerve conduction device could be used to diagnose diabetic sensorimotor polyneuropathy. RESEARCH DESIGN AND METHODS A total of 72 consecutive patients with diabetes underwent a full neurological examination and a concurrent evaluation for nine standard electrophysiological parameters using conventional nerve cond...

متن کامل

مقایسه آثار درمان هشت هفته‌ای با فلوکستین و ایمیپرامین بر قند خون ناشتا در بیماران مبتلا به افسردگی

Background: Diabetic Neuropathy is the most common and troublesome complication of Diabetes Mellitus, leading to the greatest morbidity and mortality and resulting in a huge economic burden for diabetes care. Early diagnosis of distal symmetric sensorimotor polyneuropathy, a common complication of diabetes, may decrease morbidity by allowing potential therapeutic interventions.Methods: In 68 d...

متن کامل

مقایسه معیارهای ارزیابی بالینی با یافته‌های نوروفیزیولوژیک عصب سورال در تشخیص نوروپاتی بیماران مبتلا به دیابت

Background: Diabetic Neuropathy is the most common and troublesome complication of Diabetes Mellitus, leading to the greatest morbidity and mortality and resulting in a huge economic burden for diabetes care. Early diagnosis of distal symmetric sensorimotor polyneuropathy, a common complication of diabetes, may decrease morbidity by allowing potential therapeutic interventions. Methods: In 6...

متن کامل

تعیین شیوع پلی نوروپاتی دیابتی از طریق معاینه فیزیکی و یافته های الکترودیاکنوستیک

Background and Aim: Polyneuropathy is one of the most common complications of type 2 diabetes mellitus. Clinical examination and electrophysiological findings (i.e., nerve conduction velocity) will not only provide an accurate diagnosis of neuropathy but will also help the physician in preventing and treating the disorder. The aim of the current study was to determine the prevalence of neuropat...

متن کامل

Comparison of nerve conduction studies with diabetic neuropathy symptom score and diabetic neuropathy examination score in type-2 diabetics for detection of sensorimotor polyneuropathy.

OBJECTIVE To compare the nerve conduction studies in clinically undetectable and detectable sensorimotor polyneuropathy in type 2 diabetics. METHODS Diagnosed diabetics (n = 60) were divided in two groups. Group 1 (n1 = 30) with clinically undetectable and group 2 (n2 = 30) with clinically detectable Diabetic Polyneuropathy. Detection of the sensorimotor neuropathy was done according to Diabe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Diabetes care

دوره 29 9  شماره 

صفحات  -

تاریخ انتشار 2006