Ultrasound evaluation of the airway in the ED: a feasibility study
نویسندگان
چکیده
BACKGROUND Recognition of the difficult airway is a critical element of emergency practice. Mallampati score and body mass index (BMI) are not always predictive and they may be unavailable in critically ill patients. Ultrasonography provides high-resolution images that are rapidly obtainable, mobile, and non-invasive. Studies have shown correlation of ultrasound measurements with difficult laryngoscopy; however, none have been performed in the Emergency Department (ED) using a consistent scanning protocol. OBJECTIVES This study seeks to determine the feasibility of ultrasound measurements of the upper airway performed in the ED by emergency physicians, the inter-rater reliability of such measurements, and their relationship with Mallampati score and BMI. METHODS A convenience sample of volunteer ED patients and healthy volunteers with no known airway issues, aged > 18 years, had images taken of their airway using a standardized ultrasound scanning protocol by two EM ultrasound fellowship trained physicians. Measurements consisted of tongue base, tongue base-to-skin, epiglottic width and thickness, and pre-epiglottic space. Mean and standard deviation (SD) were used to summarize measurements. Inter-rater reliability was assessed by intraclass correlation coefficients (ICCs). Analysis of variance with linear contrasts was used to compare measurements with Mallampati scores and linear regression with BMI. RESULTS Of 39 participants, 50% were female, 50% white, 42% black, with median age 32.5 years (range 19-90), and BMI 26.0 (range 19-47). Mean ± SD for each measurement (mm) was as follows: tongue base (44.6 ± 5.1), tongue base-to-skin (60.9 ± 5.3), epiglottic width (15.0 ± 2.8) and thickness (2.0 ± 0.37), and pre-epiglottic space (11.4 ± 2.4). ICCs ranged from 0.76 to 0.88 for all measurements except epiglottis thickness (ICC = 0.57). Tongue base and tongue base-to-skin thickness were found to increase with increasing Mallampati score (p = .04, .01), whereas only tongue-to-skin thickness was loosely correlated with BMI (r = .38). CONCLUSIONS A standardized ultrasound scanning protocol demonstrates that the airway can be measured by emergency sonologists with good inter-operator reliability in all but epiglottic thickness. The measurements correlate with Mallampati score but not with BMI. Future investigation might focus on ultrasound evaluation of the airway in patients receiving airway management to determine whether ultrasound can predict challenging or abnormal airway anatomy prior to laryngoscopy.
منابع مشابه
Assessment of the diagnostic capability of ultrasound in early diagnosis of nephrolithiasis: a feasibility study
متن کامل
Feasibility evaluation of trace amount of zinc in urine samples using atomic absorption solidified floating organic drop micro-extraction technique
Background: The present study was carried out with the aim of extracting trace amounts of zinc in urine samples with ultrasound-assisted emulsification solidified floating organic drop micro-extraction (USAE-SFODME) method by flame atomic absorption spectrometry (FAAS). The efficiency was investigated using the solvent extraction volume, extraction pH, time sonication and temperature extraction...
متن کاملActive anterior rhinomanometric (AAR) evaluation of nasal airway resistance in normal Iranian sample
Abstract: Background: The most important and complex phenomenon of respiratory function of the nose is related to different nasal anatomy. The differences in facial anatomic structure between different races may also be reflected in nasal resistance and airflow. Caucasians has different facial anatomic structure which is the reflection of intranasal resistance or consequence of airflow. The...
متن کاملComparative evaluation of LMA-Supreme and i-gel supraglottic airway devices with endotracheal intubation during surgical correction of traumatic orbital injuries
Aims. The aim of the study was to compare endotracheal intubation with i-gel and LMA (laryngeal mask airway) supreme supraglottic airway devices in orbital osteosynthesis surgery. Methods. 134 patients undergoing orbital plasty after fracture were enrolled in our study and were randomized into three groups: 43 in the endotracheal intubation group, 42 in the LMA-Supreme group, and 49 patients w...
متن کاملPatient effective dose evaluation for chest X-ray examination in three digital radiography centers
Background: The radiation doses resulting from diagnostic X-ray examinations are routinely measured in terms of entrance surface dose (ESD) and effective dose (ED). In this study, for the purpose of radiation protection, the radiation doses received from Digital chest X-ray examination were evaluated in terms of ESD and ED. Material and Methods: The ED was calculated by using the MCNP ...
متن کامل