Evaluation of dual-energy X-ray absorptiometry for body-composition assessment in piglets and term human neonates.

نویسندگان

  • J C Picaud
  • J Rigo
  • K Nyamugabo
  • J Milet
  • J Senterre
چکیده

The reproducibility, accuracy, and precision of dual-energy X-ray absorptiometry (DXA) was assessed by scanning 13 piglets (1471-5507 g) in triplicate. In four piglets, fat content was increased with porcine lard around the abdomen; additional measurements were performed on these animals. Reproducibility in DXA measurements from the animals without added fat was 0.09% for body weight, 1.95% for bone mineral content (BMC), and 5.35% for fat content. DXA estimates of body weight, BMC, and fat content were significantly correlated with scale body weight, ash weight, chemical calcium, and chemical fat. Body weight was measured accurately but fat content was overestimated by DXA. Mean BMC estimated by DXA represented 48% of ash weight and 215% of calcium content. The precision of DXA was 0.23% for body weight, 10.99% for ash weight, and 4.44% for calcium content. The precision of DXA for fat content was poor. However, for measurements performed in piglets with > 250 g fat, the precision was 8.85%. Thirty appropriate-forgestational-age term human neonates (birth weight: 3188 +/- 217 g) were scanned once during the first week of life. BMC and fat content were 54 +/- 6 and 470 +/- 92 g, respectively, which corresponded to 26.4 +/- 2.6 g calcium and 427 +/- 82 g fat. These were close to the reference values previously determined by chemical analysis. This study suggests that DXA is accurate and reliable for measurement of calcium and fat contents in human neonates. Further refinements would be beneficial for determining fat content in preterm human infants.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of bone mineral density with dual energy X-ray absorptiometry in pre- and post-menopausal women

Background: Osteoporosis is a chronic disease that contributes substantially to decrease physical activity and decline in the quality of life. Osteoporosis can be diagnosed easily with the use of dual-energy X-ray absorptiometry (DXA) equipment. The aim of this study was to investigate the magnitude of bone loss on proximal femur and lumbar spine LS in pre- and post-menopausal women f...

متن کامل

Comparison of Bone Mineral Density Measured by Dual X-ray, Axial Dual-energy Photon X-ray Absorptiometry and Laser Absorptiometry of Calcaneus

The objective of this study was to validate the use of bone mineral measurements of the calcaneus bone by dual X-ray and laser (DXL) in a cross-sectional study carried out in an osteoporosis clinic. Measurements of bone mineral density (BMD) at proximal femur and spine were obtained by dual-energy photon X-ray absorptiometry (DEXA). Osteoporosis was defined by a DEXA T-score <-2.5 at the femora...

متن کامل

Dual-energy X-ray absorptiometry diagnostic discordance between Z-scores and T-scores in a young Iranian population

  Background: Dual-energy X-ray Absorptiometry (DXA) is considered the gold standard for non-invasive measurement of bone mass. T-scores and Z-scores are used to present the results of bone mass. The present study was designed to evaluate the discordance between T-scores and Z-scores calculated at a same level and its relation with age, gender and body mass index (BMI) in a representative sampl...

متن کامل

Calibration and validation of EchoMRI™ whole body composition analysis based on chemical analysis of piglets, in comparison with the same for DXA.

A study was conducted to appraise a new EchoMRI™ device for body composition analysis (BCA) of infants and to compare it with dual energy X-ray absorptiometry (DXA), using chemical analysis as a reference method.The calibration part of the study included cross-validation comparisons between EchoMRI™ measurements of awake, anesthetized and dead piglets of the calibration set. It also included co...

متن کامل

Bioelectrical Impedance and Dual-Energy X-Ray Absorptiometry Assessments of Changes in Body Composition Following Exercise in Patients with Type 2 Diabetes Mellitus

We aimed to compare the level of agreement between leg-to-leg bioelectrical impedance analysis (LBIA) and dual-energy X-ray absorptiometry (DXA) for assessing changes in body composition following exercise intervention among individuals with Type 2 diabetes mellitus (T2DM). Forty-four adults with T2DM, age 53.2 ± 9.1 years; BMI 30.8 ± 5.9 kg/m(2) participated in a 6-month exercise program with ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The American journal of clinical nutrition

دوره 63 2  شماره 

صفحات  -

تاریخ انتشار 1996